Checking Burner Cap Placement
Check to make sure that there is no gap between the
burner parts. You may gently try to move the burner parts
from side to side to check if they are properly placed.

Check the Installation

Check operation of electric igniters. Check flame
characteristics. Flame should be blue with no yellow tip.
Yellow Flames:
Further adjustment is required.
Yellow Tips on Outer Cones:
Normal for LPG Gas.
Soft Blue Flames:
Normal for Natural Gas.
If the flame is completely or mostly yellow, verify that the
regulator is set for the correct fuel. After adjustment,
retest.
Some yellow streaking is normal during the initial start-
up. Allow unit to operate 4-5 minutes and re-evaluate
before making adjustments.

Removing the appliance

Disconnect the appliance from the power and the gas
supply. Push out the appliance from below.
9
CAUTION
Risk of damage! Do not lever out the appliance
from above.

Conversion to another type of gas

Conversion to another type of gas
C o n v e r s i o n t o a n o t h e r t y p e o f g a s
T he appliance must only be converted to a different type
of gas by a licensed expert.
Switch off the power supply and shut off the gas supply
before carrying out conversion.
This gas cooktop conforms to the categories indicated on
the rating plate. Changing the injection nozzles enables
the appliance to be used with all the types of gas listed
there. Conversion kits can be obtained from our after-
sales service. Some models come delivered with a
conversion kit.
The gas type is changed by:
Replacing the main control jets
Adjusting the gas valves (bypass screws)
The table shows the right combination for the relevant
gas type.
Never remove the gas valve shaft. In the event of damage
or unusual gas conversion, the entire gas valve must be
replaced. Call customer service.
9
CAUTION
To convert regulator to LP (propane) gas:
Make-Maxitrol Model RV 47 CL ½ PSIG
3.
Remove the aluminum cap from the top of the
regulator.
4.
Remove the yellow plastic shaft from the cap by
pushing it sideways until it pops out of the
groove in the cap.
5.
Turn the shaft over and push back into the
cutout in the cap.
6.
Replace the cap on the regulator.