Malfunction
The added EGC device is not
reacting to commands.
No connection between EGC
device and InScenio EGC Con-
troller.
Yellow LED is lit
The yellow LED is flashing
slowly (2 seconds on, 1 second
off).
Red LED is flashing.
The device does not start, red
LED flashing.
Cause
The EGC device has no power
supply
The data cable is interrupted.
The EGC device has no power
supply
The InScenio EGC Controller is in
the firmware update mode.
InScenio EGC Controller is
searching for a connection to
the router.
Internal error
No firmware found.
Remedy
Establish power supply
Check the EGC connections.
Establish power supply
Connect with the WIFI
„OASE_UPDATE_xxxxxx" or
„OASE_UPDATE_EGC_xxxx
xx" and use the app to start
the firmware update.
• Reduce the distance, do
not exceed the max.
range of 80 m.
• Remove any sources of
interference that may be
weakening the WIFI sig-
nal (e.g. other wireless
devices, differences in
height).
• Switch on the WIFI
router.
• Activate the WIFI func-
tion on the router.
• If the router is no longer
available or defective, re-
set the network settings
of the InScenio EGC Con-
troller so that it can be
directly controlled in ac-
cess point mode
• Connect the InScenio
EGC Controller to an-
other router
• Disconnect from the
power supply, wait for 10
seconds and then recon-
nect.
• Reset the InScenio EGC
Controller to the factory
default settings.
Manually start the firm-
ware update mode