Invacare® H335 / H345
Installing the console (R7763) (Fig. 3)
This option, when sealed to the floor, enables a
support bar (R7762, R7770, R7772 or R7773) to be
fastened in place when the wall is unsuitable for this.
1. Position the upright A.
2. The plate F resting on the floor must have its longest
side under the support bar G.
3. Mark out the location of the 4 screws.
4. Drill and insert 4 dowels appropriate to the type of floor.
5. Fix the plate to the floor using suitable screws.
6. Position the plate B with the rounded section towards
the bottom and the support bar G.
7. Fasten the plate B and the support bar G with the two
clamps C, washers E and nuts D supplied but without
tightening them.
8. With the user standing upright, without shoes, measure
the height of the upper joint of the user's thumb and
move the support bar to this height.
9. Tighten the nuts D on the two clamps C.
10. Install the socket's guard.
11. Check that the whole assembly is firm.
Installing options
The basic R7762 / H335 version can be fitted with the
following options:
A toilet paper holder (R7765) mounted on the support
bar (Fig. 4).
A soft, comfortable armpad (R7766) glued to the end of
the upper support bar (Fig. 5).
An aesthetic cover (R7767) designed to hide the lower
tube (Fig. 6).
Installing the toilet paper holder (R7765) (Fig. 4)
1. If fitted, remove the end cap I from the lower support
bar J.
2. Remove the protective cap C from the hinge piece B
using a screwdriver
3. Insert the toilet roll support A into the hinge piece B.
4. Position the spacer G and lock the assembly in place
with the fastener H.
5. Attach the hinge piece B by pressing or by tapping with
a plastic mallet to the lower support bar J and fasten
with screw D and nut E. Attach a protective cap F
on each side.
6. Check that the whole assembly is firm.
Installing the armpad (R7766) (Fig. 5)
1. If fitted, remove the black end cap D from the support
bar's upper tube C.
2. Clean the parts to be glued together with acetone before
applying the glue B.
3. Apply the whole tube of glue to the inside face of the
armpad A and position it onto the support bar C being
aligned lengthwise, ensure the armpad to point straight
upward.
4. Press it down for approximately 30 seconds.
Full adhesion is only obtained after approximately 24
hours. Invacare is not responsible for any damage
caused by improper fixing or inappropriate use.
Installing the aesthetic cover (R7767) (Fig. 6)
1. If fitted, remove the end cap, position E, from the lower
support bar A.
2. Attach the plastic over B over the lower support bar.
If necessary, use a plastic mallet to insert the cover
completely.
3. Insert the screw and the nut C and tighten.
4. Attach a protective cap D on each side.
6
Using the support folding handle
WARNING!
Risk of falling or slipping!
– Before each use, check that the support folding
handle is securely fastened and sits firmly.
1. Grab the support folding handle with one hand and
carry out the desired body movement.
Raising the support bar
1. Lift the support folding handle from the horizontal
position to its maximum vertical position. It locks
automatically in this position.
Lowering the support bar
1. Lift the support folding handle approx. 10 mm to unlock
it and hold it as it drops down to the horizontal position.
Maintenance
Maintenance and periodic inspection
The product is maintenance-free, provided the cleaning and
safety instructions outlined in this user manual are adhered
to.
WARNING!
– Before first use, clean the product thoroughly.
– Before every use, check the product for damage
and ensure that it is securely assembled.
Cleaning and disinfection
IMPORTANT!
All cleaning agents and disinfectants used must
be effective, compatible with one another and
must protect the materials they are used to clean.
For further information on decontamination in
Health Care Environments, please refer to 'The
National Institute for Clinical Excellence' guidelines
on Infection Control www.nice.org.uk/CG139 and
your local infection control policy.
– Clean by hand.
– Clean without scouring agents.
– Max. cleaning temperature 65 °C for 3 minutes.
The product can be cleaned and disinfected using
commercially available agents.
1. Disinfect the product by wiping down all generally
accessible surfaces with disinfectant.
Re-use
The product is suitable for repeated use. The number of
times it can be used depends on how often and in which
way the product is used. Before reuse, clean and disinfect
the product thoroughly.
WARNING!
Risk of injury
Worn fastening elements can suddenly come loose
and cause you to fall.
– Always use new wall plugs and bolts when
repositioning the product.
Disposal
The disposal and recycling of used devices and packaging
must comply with the applicable local legal regulations.
1572997-D