01. Press and hold down the "Set" key for approx. 3 seconds;
02. Release the key when LED "L1" starts flashing;
03. Press keys " " or " " to move from the flashing LED to L8 LED ("input LED") for the "Fault log" parameter;
04. Press and hold the "Set" key through to completion of point 06;
05. Wait approx. 3 seconds until the LEDs representing the levels corresponding to the manoeuvres with faults illuminate.
The LED L1 indicates the result of the most recent manoeuvre while L8 indicates the eighth-to-last manoeuvre.
If the LED is on this means that a fault has occurred; if the LED is off, everything is normal;
06. Press keys " " and " " to select the required manoeuvre: the corresponding LED performs a number of flashes equal
to those normally performed by the flashing light;
07. Release the "Set" key.
8

FURTHER DETAILS

The following accessories are envisaged for HYKE (optional): receivers in the
family SMXI, OXI, the programmer Oview, the solar power panel Solemyo and
buffer battery mod. PS124.

8.1 - Connecting a radio receiver

The control unit has a connector for connecting radio receivers (optional acces-
so ries) belonging to the SMXI and OXI families. To connect a receiver, discon-
nect power from the control unit and proceed as shown in fig. fig. 17. Table 11
and Table 12 show the commands corresponding to the outputs on the control
unit.
SMXI / SMXIS or OXI / OXIFM / OXIT / OXITFM in mode I or Mode II
Output no. 1
"S.S." (Step by Step) command
Output no. 2
"Partial opening 1" command
Output no. 3
"Open" command
Output no. 4
"Close" command
OXI / OXIFM /OXIT / OXITFM in extended mode II
No.
Command
Description
1
Step by step
"S.S." (Step by Step) command
2
Partial opening 1
"Partial opening 1" command
3
Open
"Open" command
4
Close
"Close" command
5
Stop
Stops manoeuvre
6
Apartment block
Apartment block control
Step by Step
7
Step by Step
Gives command even when automation is blocked
high priority
or commands are in progress
8
Partial open 2
Partial open (Opening of leaf M2 to 1/2 of normal opening)
9
Partial open 3
Partial open (Opening of two leafs to 1/2 of normal opening)
10
Open and block
It causes an opening manoeuvre, after which the automa-
automation
tion is blocked; the control unit accepts no further com-
mands with the exception of "Step by step high priority",
"Release" automation and (from Oview only) the com-
mands "Release and close" and "Release and open"
11
Close and block
It causes a closure manoeuvre, after which the automation
automation
is blocked; the control unit accepts no further commands
with the exception of "Step by step high priority", "Release"
automation and (from Oview only ) the commands
"Release and close" and "Release and open"
12
Block automation
It causes the manoeuvre to stop and the automation to
block; the control unit accepts no further commands with
the exception of "Step by step high priority", "Release" au -
to mation and (from Oview only ) the commands "Release
and close" and "Release and open".
13
Release
It causes the automation to be released and normal opera-
automation
tion to resume
Table 11
Table 12
TABLE 10 - Fault log
No.
Command
14
Courtesy light
timer on
15
Courtesy light
on-off
8.2 - Connection and installation of the back-up battery mod.
PS124
IMPORTANT! - The battery must only be connected to the control unit
after all the phases of installation and programming have been complet-
ed, as the battery constitutes a source of emergency power.
To arrange connection to the Solemyo system, follow the stages of assembly
fig. 18.
8.3 - Connection of the Oview programmer
The control unit has a BusT4 connector to which the Oview programming unit
can be connect, and which allows the complete rapid management of the
installation and maintenance phase as well as the diagnosis of the entire
automation system. To access this connector, proceed as shown in fig. 19 and
connect the connector to the dedicated seat. The Oview can be connected to
several Control units simultaneously (up to 5 without any particular precautions,
and up to 60 observing the dedicated warnings) and can stay connected to the
control unit even during the normal operation of the automation system. In this
case, it can be used to send the commands directly tot he control unit using the
specific "user" menu. The Firmware upgrade can also be carried out. If there is
a radio receiver from the OXI family in the control unit, Oview can be used to
gain access to the parameters of the transmitters stored in the receiver itself.
For further information, please consult the relevant instruction manual and the
manual for the "Opera system book" system.

8.4 - Connecting the solar power system Solemyo

CAUTION! – When the automation is powered by the "Sole myo" system,
IT MUST NEVER BE POWERED simultaneously by the electrical mains.
For more information on the Solemyo system, refer to the relative instruction
manual.
To connect the Solemyo system, proceed as shown in fig. 20

8.5 - Connecting the external release system Kio

CAUTION! – Kio must be connected to the gearmotor controlling the leaf
that moves first (starting from the gate closed position).
01. Open the cover of the gearmotor (fig. 21-1).
02. Remove the plastic guard of the gearmotor as shown in fig. 21-2;
03. Insert the screw with nut in the hole as shown in fig. 21-3;
04. Attach the two ends of the spring as shown in fig. 22-4;
05. Insert the steel cable before the screw and then in the hole of the pin as
shown in fig. 21-5;
06. Secure the cable by tightening the relative screw (fig. 21-5);
07. Route the other end of the cable through one of the holes on the lower sec-
tion of the gearmotor as shown in fig. 21-6;
08. Refit the plastic guard and then the cover of the gearmotor (fig. 21-7);
09. At this point, connect the cable to Kio, with reference to the relative instruc-
tion manual.
SET
L1
or
SET
3 s
and
SET
Description
The Courtesy light comes on with timed turning off
The Courtesy light turns on and off in step-by-step mode
3 s
SET
L8
English – 11

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Hyke hk7224

Table des Matières