1. Before starting, check that there are no water leaks and
that the electrical components are dry.
2. DO NOT connect power if the humidifier is damaged or
even partially wet!
When installation is completed, flush the supply pipe for
10 minutes by piping water directly into the drain without
sending it into the humidifier. This will eliminate any scale or
residue that may cause foam when boiling.
4.1

START-UP CHECKLIST

Before starting the humidifier, the following should be
checked:
1. Water is connected, the line has been flushed, and external
valves are open.
2. The drain hose is installed with no kinks or restrictions and
run to an open drain or condensate pump.
3. Electricity is connected in accordance with instructions,
local codes and data labels in the unit.
4. The power fuses are installed and intact.
5. All AWG12 control wiring is done and tested.
6. The airflow switch (if installed) is wired to open on air flow
loss.
7. The high limit humidistat (if installed) is wired to open on
humidity rise above set point.
8. Control board wires should be checked to make sure all
connectors are tight.
9. The steam hose and drain hose (and condensate hose, if
installed) is run correctly with no sags or kinks and sloped
properly according to the manual.

4. START UP

4.2

STARTING THE HUMIDIFIER

• Ensure that the external power is turned on.
• Push the top part of the ON/OFF button so that the "1" part is
in (See item #13 in Fig. 4.a.). The yellow power LED will be lit.
The 5500 Steam Humidifier is now ready to operate.
• When there is a call for humidity, the 5500 Steam Humidifier
will close its power relays and send power to the electrodes
in the plastic steam cylinder. The green Operation LED will
light, indicating that operation has begun.