Model GF3200DMD & GF4200DMD
Evaporative Humidifier Installation Manual
Please Read And Save These Instructions
GF4200DMD
CAUTION!
!
This symbol and the word "CAUTION" indicates:
IMPORTANT INSTRUCTIONS!
Failure to heed
Inside the Box:
 Humidifier (Model GF3200DMD or GF4200DMD)
 GFGA10 Vapor Pad
(For Model GF3200DMD) OR
®
 GFGA35 Vapor Pad
(For Model GF4200DMD),
®
 Solenoid valve assembly
 Integral bypass damper
 Humidistat
 24V transformer
 Push-to-connect tee valve
 Hardware
 1/4" Diameter plastic supply tubing for hot or cold water applications
6" Diameter flexible by-pass duct assembly
 Electrical wire
 10' plastic drain hose
Not Included:
 6" diameter rigid or flexible bypass duct
 Wire Nuts
 24V current sensing relay (GF-GA50) or air proving switch (GF-12502)
WARNING: Do not install where ambient temperatures fall below 32°F / 0°C or where plenum temperatures exceed 200°F / 93°C.
!
For maximum evaporative capacity, install this humidifier on the warm air supply plenum.
Form No. 4200-18 RevC Canada
Canadian General Filters
Limited
GF3200DMD
!
!
CAUTION! or
WARNING! can result in serious injury or death.
Canadian General Filters, Ltd.
400 Midwest Rd.
Toronto, ON M1P3A9 Canada
Toll Free: (888) 216-9184
www.generalaireiaq.ca
Plenum Installation Location:
GF-3200DMM & GF-4200DMM humidifiers may be installed on
either the return or supply plenum of a forced air handling system.
The Humidifier bypass panel is reversible and can be mounted
on the right or left side of the humidifier. Select a location for the
humidifier that allows for service and maintenance.
Supply
Return
Vertical
Installation
Options
Drain Line
WARNING!
!
This symbol and the word "WARNING" indicates:
IMPORTANT INSTRUCTIONS!
WARNING:
DISCONNECT ELECTRICAL POWER
!
BEFORE BEGINNING INSTALLATION.
!
To ensure your safety and the longevity
IMPORTANT:
of your unit, we recommend:
Contacting a licensed contractor to perform
maintenance or repairs.
Changing your Vapor Pad
heating season.
Models
Return
Supply
Drain Line
Horizontal Installation
at the start of each
®
®
®

Publicité

loading

Sommaire des Matières pour GeneralAire GF4200DMD

  • Page 1 WARNING! can result in serious injury or death. Inside the Box: • WARNING:  DISCONNECT ELECTRICAL POWER  Humidifier (Model GF3200DMD or GF4200DMD) BEFORE BEGINNING INSTALLATION.  GFGA10 Vapor Pad (For Model GF3200DMD) OR ®  GFGA35 Vapor Pad (For Model GF4200DMD), ®...
  • Page 2 Model GF-3200DMD & GF-4200DMD Humidifier Installation Manual INSTALLATION Return Supply CUT HUMIDIFIER AND BYPASS HOLES IN DUCT Using the supplied template, cut the rectangular opening 9.13" in the Return or Supply (shown) duct. Cut the 6” round hole in the opposite duct. Locate it 10” to 15” from side of the 6"...
  • Page 3 INSTALLATION INSTALL THE PUSH-TO-CONNECT VALVE I. Select desired valve location. II. Remove 0.6" (15mm) of pipe to account for valve width (Fig. E). Fig. E Make sure both pipe ends are square, deburred and clean. III. Mark both pipes at the insertion depth, 0.95" (24mm) (Fig. F). Fig.
  • Page 4 MHX3C Humidistat MHXC3 Humidistat • If 120V HUM terminal is used, please use 24VAC transformer provided. GeneralAire Humidifier Wire GeneralAire® Humidifier ®  WARNING: ALL WIRING SHOULD COMPLY WITH LOCAL ELECTRICAL CODES. Splices Furnace Blue Wires Fig.
  • Page 5 AVERTISSEMENT! peut entraîner des blessures graves ou la mort. Inclus dans la boîte: • AVERTISSEMENT: DÉBRANCHER L'ALIMENTATION  ÉLECTRIQUE AVANT DE COMMENCERL'INSTALLATION. Humidificateur (GF3200DMD ou GF4200DMD) Vapor Pad GF-GA10 (pour modèle GF-3200DMM) OU ® Vapor Pad GF-GA35 (pour modèle GF-4200DMM), ®...
  • Page 6 Modèle GF-3200DMM & GF-4200DMM d'Humidificateur Manuelle d'installation INSTALLATION Retour Alimentation INSTALLATION D'ALIMENTATION OU RETOUR: Découpez un trou rectangulaire en utilisant le gabarit fourni par le fabricant et un deuxième trou rond de 6 po; de 10 à 15 po du côté de 9.13"...
  • Page 7 INSTALLATION INSTALLER LA VANNE PUSH-TO-CONNECT I. Sélectionnez l’emplacement de la vanne souhaitée. Fig. E II. Retirez 0,6 po (15 mm) de tuyau pour tenir compte de la largeur de la vanne (Fig. E). Assurez-vous que les deux extrémités du tuyau sont carrées, ébavurées et propres. III.
  • Page 8 ® MHX3C Humidistat MHXC3 Humidistat De l'humidostat Épissures GeneralAire Humidificateur Wire GeneralAire ® ® Humidifier GeneralAire® Humidifier De Fil Splices 6" Furnace Fils bleus Blue Wires d'électrovanne 24 V Ligne de vidange Fig. I Fig. H * Terminal W : •...

Ce manuel est également adapté pour:

Gf3200dmd