INSTALL THE PUSH-TO-CONNECT VALVE
I. Select desired valve location.
II. Remove 0.6" (15mm) of pipe to account for valve width (Fig. E).
Make sure both pipe ends are square, deburred and clean.
III. Mark both pipes at the insertion depth, 0.95" (24mm) (Fig. F).
IV. Firmly insert both pipes into fitting until at full depth.
Verify each pipe is fully inserted. The depth mark will
be within 0.005" (0.13mm) of the release collar (Fig. G).
6
CONFIGURE WATER SUPPLY TUBING
I. Utilizing copper tubing requires a brass compression
nut and brass sleeve.
II. Utilizing plastic tubing requires a plastic sleeve on the
outside with a brass compression nut.
7
CONNECT THE DRAIN HOSE
Connect the 1/2" ID drain hose to the spout on the humidifier cabinet
using the provided flat spring clip. Run the drain hose to a suitable
drain such as floor drain, laundry sink or to a condensate pump (sold
separately). Be sure the hose has continuous slope and is not kinked at
any point.