Model 1137 Humidifier GFI #5137 Installation & Owners Manual Read and Save These Instructions • Installation by anyone other than a qualified contractor voids the warranty. • Product designed for residential installation only. Commercial installation voids warranty. • Modification or alteration of product, parts, installation instructions or local safety codes voids warranty. • Read our full warranty policy at the end of this document. Breathe Healthier General Filters, Inc. Canadian General Filters, Ltd. 43800 Grand River Avenue 400 Midwest Rd. Novi, Michigan 48375...
Model 1137 Humidifier Installation Manual 1137 Table of Contents Subject Page # Specifications Unit Location Additional Materials That May Be Necessary Installation Installation Cont. Saddle Valve / Solenoid Valve Installation Installation Cont. Installing / Wiring The Control Installation Cont. How the Humidifier Works...
Model 1137 Humidifier Installation Manual Specifications • Model: 1137 Legacy Flow Through Humidifier (GFI #5137) • Type: Fan Powered Flow Through • GPD: 18 Based on 120° F Plenum Temperature • Warranty: 5 Years • Replacement Vapor Pad : 990-13 (GFI#7002) ®...
Model 1137 Humidifier Installation Manual Installation Cont. Thumb Nuts Cabinet Screws 2. Cut out center section. Install one cabinet retaining clip in each of the two top holes to assist holding cabinet while installing six cabinet screws. Install drain pan, evaporator Distributor pad and distributor trough using thumb nuts provided.
Model 1137 Humidifier Installation Manual Installation Cont. Distributor 4. Assemble distributor tube so that it is directed into the Trough Cover center opening of the distributor trough cover. Distributor Tube (Metal) 5. Connect 1/4" water supply tube to brass filter at inlet of solenoid.
Model 1137 Humidifier Installation Manual Installation Cont. 7. Connect drain hose to 5/8" spout on humidifier cabinet using hose clamp provided. Run 5/8" hose to suitable drain such as floor drain, sewer or laundry sink. Be sure hose has continuous slope and is not kinked at any point.
Model 1137 Humidifier Installation Manual Maintenance Your Humidifier is engineered to give helpful and trouble-free humidification. For maximum efficiency the following cleaning procedures should be carried out at the end of each heating season: 1. Turn off water supply and electrical power to humidifier.
Model 1137 Humidifier Installation Manual Troubleshooting 1. My humidifier continues to run. Check for the following: • The valve might be stuck in the "open" position. • Check for wiring errors. • Is the unit sized properly for your home? If it is rated for a smaller-sized home than the home in which it is installed, it will work "overtime"...
5. Dry air can cause harm to expensive musical instruments like pianos and violins. 6. Dry air causes gaps in window & door frames, letting cold outdoor air in; causing you to turn up the heat and increasing your heating bills! Controlled humidity from a GeneralAire Humidifier allows you the ®...
What is Covered • Five Years: The 1137, if properly registered by the return of the warranty registration card to the manufacturer, is warranted by General Filters, Inc. (“Company”) for a period of five (5) years from the date of the original installation, when installed in residential applications only (“Limited Warranty Period”).
• Any questions pertaining to this limited warranty should be addressed to the manufacturer. (U.S.A.: The manufacturer has elected not to make available the informal dispute settlement mechanism which is specified in the Magnuson-Moss Warranty Act.) The rest of this page left intentionally blank. FORM NO. 1137 _ 47_ REV J (8-2018; JPF; InDesign)
6. REMOVE HUMIDIFIER, DRILL REMAINING HOLES AND CUT OUT CENTER SECTION OF TEMPLATE. CUT ON THIS LINE TEMPLATE NO. 1137 IF FURNACE JACKET EXTENDS MORE THAN 3" OUTWARD FROM THE PLENUM SURFACE ALLOW 4" CLEARANCE BELOW THIS LINE FOR EASY ACCESS TO DRAIN HOSE CONNECTION.
M SÉRIE HUMIDOSTAT OU D’AUTRES HUMIDOSTAT MANUAL HUMIDIFICATEUR FILS DE CONTRÔLE. JAUNE FILS. CONNECT TO HUMIDOSTAT. 24V SORTIE DE HUMIDIFICATIUR. ROUGE FILS. NON UTILISÉ, SEPARATE CAP OU INDIVIDUELLEMENT. Monter le tuyau du distributeur de façon qu'il se dirige vers l'ouverture E SÉRIE HUMIDOSTAT centrale du couvercle du bac de distributeur.
1099-9 ÉCROU À AILETTES 1137-35 COUVERCLE DU BAC 1137-4 GOULOTTE DU DISTRIBUTEUR 1137-2 TUYÈRE DU VENTILATEUR 990-13 BLOC ÉVAPORATEUR 1137-9 PALE DE VENTILATEUR 1137-20 GRILLE DE PROTECTION DU VENTILATEUR 990-53 VANNE ÉLECTROMAGNÉTIQUE 1137-7 SUPPORT DE CÂBLAGE 40-7 ÉCROU TINNERMAN 1137-8 MOTEUR DU VENTILATEUR...
GENERAL FILTERS, INC. CANADIAN GENERAL FILTERS, LTD. NOVI, MICHIGAN 48375-1115 SCARBOROUGH, ONTARIO M1R3B7 WWW.GENERALAIRE.COM WWW.CGFPRODUCTS.COM SOINS ET ENTRETIEN Votre humidificateur est conçu pour fournir une humidification d'appoint sans problèmes. Pour bénéficier d'un fonctionnement maximum, suivre les étapes de nettoyage ci-dessous à la fin de chaque saison froide ! 1.