Télécharger Imprimer la page
Masquer les pouces Voir aussi pour 1000 Serie:

Publicité

Les langues disponibles

Les langues disponibles

Liens rapides

Fr esh I ndoor Air Quali t y
INSTALLER: PLEASE FILL OUT AND MAIL GUARANTEE CARD AFTER INSTALLATION
IS COMPLETE. LEAVE INSTALLATION INSTRUCTIONS WITH HOME OWNER
PRECAUTION: The installer should be an experienced service technician. Disconnect electrical power before
beginning installation. Do not install where temperatures fall below 32 degrees F or where plenum temperatures
exceed 200 degrees F. For maximum evaporative capacity, install this humidifier on the warm air supply plenum.
When wiring into a multi-speed blower circuit see Step 6C & 6D.
ADDITIONAL MATERIALS THAT MAY BE NECESSARY:
1. 1/4" diameter plastic supply tubing or 1/4" copper supply tubing for hot water applications
2. air pressure switch (G.F. Model #12500 suggested)
1
Select location on vertical surface of warm air plenum for mounting
humidifier. Tape mounting template in place making sure the template is
level. Do not install humidifier where the blanked off ends of a cooling coil
will restrict air flow to the humidifier. Cut out center section of template.
3
Mount the self tapping saddle valve on either a cold or a hot water pipe.
A side or top mount is best to avoid clogging from pipe sediment.
Connect 1/4" O.D. tubing to the saddle valve. Copper tubing requires a
brass compression nut and brass sleeve. Plastic tubing requires a brass
insert inside the tubing, a plastic sleeve on the outside with a brass
compression nut.
NOTE: DO NOT USE PLASTIC TUBING ON HOT WATER OR IN
CONTACT WITH ANY HOT PLENUM SURFACE OR DUCT.
INSTALLATION OF THIS SADDLE VALVE MUST MEET OR EXCEED
LOCAL CODES AND ORDINANCES.
4
Connect
1/4" water supply tube to inlet of solenoid.
PLASTIC TUBING IN CONTACT WITH ANY HOT PLENUM
SURFACE OR DUCT. IF USING PLASTIC TUBING, USE TUBE
SUPPORT P189 AND PLASTIC COMPRESSION SLEEVE P190.
Connect drain hose to 1/2" spout on humidifier cabinet using hose clamp if
necessary. Run 1/2" hose to suitable drain such as floor drain, sewer or
laundry sink. Be sure hose has continuous slope and is not kinked at any point.
COPPER
TUBING
PLASTIC
TUBING
DO NOT USE
3. junction box, 115 V. grounding outlet, cover and wire
4. 1/2" I.D. drain hose
5. #8 x 3/4" mounting screws
2
Open cover and remove evaporator pad assembly.
chassis is self retaining, slide top side in first then slide chassis
down. Level chassis and install eight screws.
SADDLE VALVE INSTALLATION INSTRUCTIONS
Copper Pipe
1. Retract piercing pin into valve body by turning handle
counterclockwise.
2. Screw valve body into upper bracket and tighten.
3. Place rubber gasket over piercing pin.
4. Assemble saddle valve over copper pipe using enclosed screen,
nuts and lower bracket.
5. Tighten screws evenly and firmly. Brackets should be parallel.
6. Complete compression connection to saddle valve outlet.
7. Turn handle clockwise to pierce tubing and close saddle valve.
8. Turn handle counterclockwise to open saddle valve, leave open for �
several seconds to flush dirt from pipe and tubing.
Steel, Brass or Hard Plastic Pipe
1. Shut off water supply and drain pipe.
2. Turn handle clockwise to expose piercing pin and close saddle
valve.
3. Place rubber gasket over piercing pin.
4. Drill 1/8" hole in pipe using a hand crank drill to avoid shock hazard.
5. Assemble saddle valve over steel, brass or hard plastic pipe using �
enclosed screws, nuts and lower bracket.
6. Tighten screws evenly and firmly. Brackets should be parallel.
7. Complete compression connection to saddle valve outlet.
8. Turn handle counterclockwise to open saddle valve, leave open for �
several seconds to flush dirt from pipe and tubing.
Threaded Pipe Fittings
1. Turn handle clockwise to expose piercing pin and close saddle
valve.
2. Seal valve body threads using pipe tape or sealant.
3. Install valve into 1/8" NPT fitting.
4. Complete compression connection to saddle valve outlet.
5. Turn handle counterclockwise to open saddle valve, leave open for
several seconds to flush dirt from pipe and tubing.
1000 SERIES
FLOW THROUGH
POWER HUMIDIFIER
FOR INSTALLATION ON A VERTICAL
SURFACE OF THE WARM AIR PLENUM
OF ANY FORCED AIR FURNACE
1
2
Humidifier

Publicité

loading

Sommaire des Matières pour GeneralAire 1000 Serie

  • Page 1 1000 SERIES FLOW THROUGH Fr esh I ndoor Air Quali t y INSTALLER: PLEASE FILL OUT AND MAIL GUARANTEE CARD AFTER INSTALLATION POWER HUMIDIFIER IS COMPLETE. LEAVE INSTALLATION INSTRUCTIONS WITH HOME OWNER FOR INSTALLATION ON A VERTICAL PRECAUTION: The installer should be an experienced service technician. Disconnect electrical power before SURFACE OF THE WARM AIR PLENUM beginning installation.
  • Page 2 E2 HUMIDISTAT 1. Follow the installation instructions supplied with the humidistat. 2. To remove the humidistat from the base, squeeze the louvered base at the top and bottom. Before wall mounting, please remove the gasket. OUTDOOR TEMP. SENSOR � (NOT USED IN MANUAL MODE) 4.
  • Page 3 HUMIDIFICATEUR PUISSANT À CIRCULATION DIRECTE Fr esh I ndoor Air Quali t y INSTALLATEUR : VEUILLEZ REMPLIR ET POSTER LA CARTE DE GARANTIE UNE FOIS L'INSTALLATION 1000 SÉRIES TERMINÉE. LAISSER LES DIRECTIVES D'INSTALLATION AU PROPRIÉTAIRE DE LA MAISON. PRÉCAUTION : L'installateur doit être un technicien qualifié et expérimenté. Couper l'alimentation électrique POUR L'INSTALLATION SUR UNE avant de commencer l'installation.
  • Page 4 Raccorder le tuyau d'alimentation d'eau de 1/4 po au filtre en laiton de l'entrée du solénoïde. AUCUN TUYAU EN PLASTIQUE NE DOIT ENTRER EN CONTACT AVEC DES CONDUITS OU DES SURFACES DE PLÉNUM CHAUDS. Si à l'aide de la tuyauterie en plastique, employez l'appui de tube fourni, P189. Raccorder le boyau de vidange au bec de 1/2 po sur l'humidificateur à...
  • Page 5 PARTS LIST FOR HUMIDIFIER 900-9 NOZZLE 900-40 PAD RAIL 900-10 SPOUT GA19 EVAPORATOR PAD 900-15 DISTRIBUTOR TROUGH GA4247 FAN BLADE GA4237 MOTOR 900-16 NAMEPLATE 1000-11 HARNESS - BOARD GA4238 RELAY ASS'Y 900-14 DRAIN PAN 1137-31 POWER SUPPLY CORD GA4231 ORIFICE - YELLOW P-190 COMPRESSION SLEEVE (PLASTIC) P-101 COMPRESSION NUT GA4235 DISTRIBUTOR TUBE...
  • Page 6 GENERAL FILTERS, INC. CANADIAN GENERAL FILTERS, LTD. NOVI, MICHIGAN 48375-1115 SCARBOROUGH, ONTARIO M1R3B7 WWW.GENERALAIRE.COM WWW.CGFPRODUCTS.COM CARE AND MAINTENANCE Your Humidifier is engineered to give helpful and trouble-free humidification. For maximum efficiency the following cleaning procedures should be carried out at the end of each heating season: 1.
  • Page 7 Remettre en place l’assemblage du patin d’évaporateur et le couvercle de l’humidificateur. IInsérer le faisceau de câblage à six connecteurs basse tension du couvercle dans le faisceau du solénoïde. Ouvrir l'eau et brancher le cordon d'alimentation pour vérifier le fonctionnement de l'humidificateur. Régler l'humidistat en mode de demande.
  • Page 8 GENERAL FILTERS, INC. CANADIAN GENERAL FILTERS, LTD. NOVI, MICHIGAN 48375-1115 SCARBOROUGH, ONTARIO M1R3B7 WWW.GENERALAIRE.COM WWW.CGFPRODUCTS.COM SOINS ET ENTRETIEN Votre humidificateur est conçu pour fournir une humidification d'appoint sans problèmes. Pour bénéficier d'un fonctionnement maximum, suivre les étapes de nettoyage ci-dessous à la fin de chaque saison froide ! 1.