This humidifier, if properly registered by the return of the warranty registration card to the manufacturer, is warranted to the consumer against defects in
materials and workmanship for a period of ten years from the date of installation. Evaporator pads, water strainers or metering orifices are not covered by
this limited warranty or any other warranties. Any other defective parts will be repaired without charge except for removal, reinstallation and
transportation costs. To obtain repair service under this limited warranty, the consumer must send the defective part or the complete humidifier to the
manufacturer.
THERE ARE NO EXPRESS WARRANTIES COVERING THIS AIR CLEANER OTHER THAN AS SET FORTH ABOVE, THE IMPLIED WARRANTIES OF
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE EXPRESSLY EXCLUDED. THE MANUFACTURER ASSUMES NO
LIABILITY IN CONNECTION WITH THE INSTALLATION OR USE OF THIS PRODUCT, EXCEPT AS STATED IN THIS LIMITED WARRANTY. THE
MANUFACTURER WILL IN NO EVENT BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES.
This limited warranty gives you specific legal rights, and you may also have other rights which vary from state to state. Some states do not allow either
limitations on implied warranties, or exclusions from incidental or consequential damages, so the above exclusion and limitation may not apply to you.
Any questions pertaining to this limited warranty should be addressed to the manufacturer. (U.S.A.: The manufacturer has elected not to make available
the informal dispute settlement mechanism which is specified in the Magnuson-Moss Warranty Act.)
GENERAL FILTERS, INC.
NOVI, MICHIGAN 48375-1115
WWW.GENERALAIRE.COM
Your Humidifier is engineered to give helpful and trouble-free humidification. For maximum efficiency the following cleaning procedures should be carried
out at the end of each heating season:
1. Turn off water supply and electrical power to humidifier.
2. Remove cover, water distributor trough, evaporator pad, pad rails and drain pan. Clean excessive mineral
deposits from the distributor trough, drain pan, pad rails and humidifier cabinet. A solution of 1/2 vinegar & 1/2
water will help loosen mineral deposits. Inspect drain hose, clean or replace as necessary.
3. If the evaporator pad has excessive mineral deposits, replace with a new "GA19" evaporator pad. Install
trough, pad rails and drain pan. Replace cover, reconnect electrical plug..
4. In heavy mineral areas or if the solenoid valve fails to function disconnect the 1/4" water supply line from the
solenoid valve. Carefully pull the strainer screen (P.N. 900-8) from the valve body (P.N. 900-6). Clean the
mineral deposits from all parts. If the orifice is clogged, it may be opened by inserting a small pin. Reinsert the
filter into the valve body.
5. Reconnect the 1/4" water line to the solenoid valve if necessary. Turn on the water supply and check all points
for leakage. The operation of the unit may be checked by starting the furnace. The humidifier operates only
when the furnace blower is running or the burner circuit is energized. The humidifier is now ready for operation.
6. During the summer, turn off water supply and electrical power to humidifier.
LIMITED WARRANTY
CARE AND MAINTENANCE
CANADIAN GENERAL FILTERS, LTD.
SCARBOROUGH, ONTARIO M1R3B7
HOW THE HUMIDIFIER WORKS
The operating principle of the humidifier is based on the most efficient
and economical means of evaporating water to the air.
necessary for evaporating water is produced by the furnace.
The water supply to the humidifier is controlled by the electric solenoid
valve.
The solenoid valve and humidifier fan are controlled by a
humidistat connected through an isolation relay.
designed for wall mounting in the living area or surface mounting on the
return air duct. ELECTRICAL RATING: 24 VAC/ 60 Hz.
DO NOT SET RELATIVE HUMIDITY TOO HIGH DURING COLD
WEATHER. EXCESSIVE HUMIDITY MAY CAUSE CONDENSATION
ON WINDOWS OR IN WALLS.
SETTINGS AS DESCRIBED IN THE HUMIDISTAT OWNERS
MANUAL.
Water flows through a strainer, is metered through an orifice to provide
the proper amount of water, and is supplied to the evaporator pad by
the distributor trough. Air from the warm air plenum is pulled through
the wetted evaporator pad by the humidifier fan and returned to the
warm air plenum to be circulated through the living area. Moisture is
evaporated to the air passing through the evaporator pad.
Minerals are not blown into the air stream as occurs in atomizing
humidifiers; they are left on the evaporator pad where a high
percentage is carried off with the waste water.
When the humidifier is installed and operating, no adjustments are
necessary other than setting the control knob on the humidistat to the
desired level of humidification.
To turn the humidifier off, close water supply valve, switch electrical
power off and turn humidistat off.
WWW.CGFPRODUCTS.COM
AT
RECOMMENDED
OUTSIDE
SETTING
TEMPERATURE
-20ϒ F -29ϒ C
15%
-10ϒ F -23ϒ C
20%
0ϒ F -18ϒ C
25%
+10ϒ F -29ϒ C
30%
+20ϒ F - 7ϒ C
35%
+30ϒ F - 1ϒ C
40%
The heat
The humidistat is
REFER TO RECOMMENDED