Precautions and safety
regulations when using the
vacuum cleaner
When dust removers are used,
the rate at which air is ex-
changed in the room must be
adequate if the exhaust air from
the vacuum cleaner is blown into
the room (please observe regu-
lations valid in your country).
Before start-up
Inspect power cord regularly to
detect signs of damage, e.g.
cracks or ageing.
If the power cord is damaged, it
must be replaced by the Service
or an electrician to avoid danger
before use of the vacuum clean-
er is continued.
Use only the type of power cord
specified in the operating man-
ual.
Do not damage the power cord
(e.g. by moving over it or pulling
or crushing it).
Disconnect the power cord by
pulling the plug only (do not pull
or tug the power cord).
Inspect the vacuum cleaners to
ensure that they are in proper
condition. Plugs and couplings
in power cords must at least
have splash protection.
Never use the vacuum cleaner
if the filter element is damaged.
Picking up liquids
If foam develops or liquid
emerges, stop work immediately
and empty the dirt tank.
Regularly clean the built in level
indicator hose to limit the wa-
ter level and check that it is not
damaged.
See section 5 for information on
handling liquids and (hazard-
ous) dust.
Before starting work, the operat-
ing staff must be informed on
– use of the vacuum cleaner
– risks associated with the ma-
terial to be picked up
– safe disposal of the picked
up material.
Electrical components
Check the rated voltage of the
vacuum cleaner before con-
necting it to the mains supply
system. Ensure that the voltage
shown on the rating plate corre-
sponds to the voltage of the lo-
cal mains power supply.
If you are using an extension
cord, use only those specified
by the manufacturer or higher
quality ones (see section 9.4
„Technical data").
It is recommended that the vac-
uum cleaner should be connect-
ed via a residual current circuit
breaker. This stops the supply
of electricity if the leakage cur-
rent to earth exceeds 30 mA for
30 ms or it has an earth tester
circuit.
When using an extension lead,
check the minimum cross-sec-
tions of the cable:
Cable length
Cross section
m
<16 A
up to 20 m
ø1.5mm²
20 to 50 m
ø2.5mm²
Arrange the electrical parts
(sockets, plugs and couplings)
and lay down the extension lead
so that the protection class is
maintained.
Never spray water on to the
upper section of the vacuum
cleaner. Danger for persons,
risk or short-circuiting.
Observe the latest edition of the
IEC regulations.
MAKITA 447 M
english
<25 A
ø2.5mm²
ø4.0mm²
3