Thank you for buying this product, our company is sure that you will be more
than satisfied with its performance.
This product is supplied with an "Instruction Manual" which should be read
carefully as it provides important information about safety, installation, ope-
ration and maintenance.
This product complies with recognised technical standards and safety
regulations. We declare that it is in conformity with the following European
Directives: 89/336/EEC, 73/23/EEC and subsequent amendments.
1) GENERAL SAFETY
WARNING! An incorrect installation or improper use of the product
can cause damage to persons, animals or things.
The "Warnings" leaflet and "Instruction booklet" supplied with this
product should be read carefully as they provide important information
about safety, installation, use and maintenance.
Scrap packing materials (plastic, cardboard, polystyrene etc) according
to the provisions set out by current standards. Keep nylon or polystyrene
bags out of children's reach.
Keep the instructions together with the technical brochure for future
reference.
This product was exclusively designed and manufactured for the use
specified in the present documentation. Any other use not specified in
this documentation could damage the product and be dangerous.
The Company declines all responsibility for any consequences resulting
from improper use of the product, or use which is different from that
expected and specified in the present documentation.
Do not install the product in explosive atmosphere.
The construction components of this product must comply with the
following European Directives: 89/336/CEE, 73/23/EEC, 98/37/EEC
and subsequent amendments. As for all non-EEC countries, the above-
mentioned standards as well as the current national standards should
be respected in order to achieve a good safety level.
The Company declines all responsibility for any consequences resulting
from failure to observe Good Technical Practice when constructing closing
structures (door, gates etc.), as well as from any deformation which might
occur during use.
The installation must comply with the provisions set out by the following
European Directives: 89/336/CEE, 73/23/EEC, 98/37/EEC and subse-
quent amendments.
Disconnect the electrical power supply before carrying out any work on
the installation. Also disconnect any buffer batteries, if fitted.
Fit an omnipolar or magnetothermal switch on the mains power supply,
having a contact opening distance equal to or greater than 3,5 mm.
Check that a differential switch with a 0.03A threshold is fitted just before
the power supply mains.
Check that earthing is carried out correctly: connect all metal parts for
closure (doors, gates etc.) and all system components provided with
an earth terminal.
Fit all the safety devices (photocells, electric edges etc.) which are needed
to protect the area from any danger caused by squashing, conveying and
shearing, according to and in compliance with the applicable directives
and technical standards.
Position at least one luminous signal indication device (blinker) where it
can be easily seen, and fix a Warning sign to the structure.
The Company declines all responsibility with respect to the automation safety
and correct operation when other manufacturers' components are used.
Only use original parts for any maintenance or repair operation.
Do not modify the automation components, unless explicitly authorised
by the company.
Instruct the product user about the control systems provided and the
manual opening operation in case of emergency.
Do not allow persons or children to remain in the automation operation area.
Keep radio control or other control devices out of children's reach, in
order to avoid unintentional automation activation.
The user must avoid any attempt to carry out work or repair on the automation
system, and always request the assistance of qualified personnel.
Anything which is not expressly provided for in the present instructions,
is not allowed.
Installation must be carried out using the safety devices and controls
prescribed by the EN 12978 Standard.

1) GENERAL OUTLINE

The ALTAIR-P control panel is suitable for swing gates. It is supplied by the
manufacturer with standard functional settings. Any alteration must be set by
means of the incorporated display programmer or by means of
programmer. The Control unit completely supports the EELINK protocol.
Specifications:
-
management of two motors with electronic torque setting.
-
Radio receiver: 433.92 MHz rolling-code or fixed code
-
Maximum numbers of radio control devices to be managed: 63
-
Centralised controls with other controllers: presetting for serial protocol
with an external accessory.
INSTALLATION MANUAL
3) CONTROL UNIT TEChNICAL SPECIFICATIONS
Power supply: .............................................................. 230V
No-load absorption from the mains: ............................................. 0.2A max
Mains/low voltage insulation: ....................................... > 2MOhm 500V
Dielectric strength: ..........................mains/low voltage 3750V~ for 1 minute
Motor output current: ........................................................1.25A+1.25Amax
Motor relay commutation current: .......................................................... 10A
Maximum power with 2 motors: ...............................................300W+300W
Maximum power with 1 motor: .......................................................... 300W
Blinker: ........................................................................................ 40W max
Gate-open warning light:....................................................... 24V
Supply to accessories: ...................................24V
Degree of protection for box: .............................................................. IP 55
Dimensions: ...............................................................................see figure 1
Fuses: .......................................................................................see figure 2
(*other voltages available on request)
4) TERMINAL BOARD CONNECTIONS (Fig.3)
WARNING - During wiring and installation operations, refer to the current
standards and to principles of good technical practice.
Wires powered at different voltages must be physically separated, or suitably
insulated with at least 1 mm extra insulation. The wires must be clamped by
an extra fastener near the terminals, for example by bands.
The capacitors must be inserted inside the control unit box and adequately
fixed to it.
WARNING! For connection to the mains, use a multipolar cable with a
minimum of 3x1.5mm
sly mentioned regulations. For example, if the cable is out side (in the
open), it has to be at least equal to h07RN-F, but if it is on the inside
(or outside but placed in a plastic cable cannel) it has to be or at least
egual to h05VV-F with section 3x1.5mm
TERMINAL
1
2
3
4-5-6
7-8-9
10-11
13-14
15-16
17-18
17-19
17-20
17-21
31-32
universal palmtop
5) PROGRAMMING
The control panel provided with a microprocessor is supplied with function
parameters preset by the manufacturer, suitable for standard installations. The
predefined parameters can be altered by means of either the incorporated
display
universal palmtop
In the case where programming is carried out by means of
2
cross section and complying with the previou-
2
.
DESCRIPTION
GND terminal
(yellow/green earthing cable)
Single-phase mains supply (L)
Single-phase mains supply (N)
Connection to motor 1:
4 on 1 + Capacitor
5 common
6 on 2 + Capacitor
Connection to motor 2:
7 on 1 + Capacitor
8 common
6 on 2 + Capacitor
~
230V
output for blinker light (40W max)
~
24V
180mA max output – supply to photocells or other
devices
~
Output (N.O. contact (24V
/0.5A max)) for gate-open war-
ning light or, alternatively, 2nd radio channel (see paragraph
6 "configuration").
STOP push (N.C.) input. If not used, leave the bridge
connected.
PHOTOCELL (N.C.) input. If not used, leave the bridge
connected
DIP START-OPEN= OFF:
START push (N.O.).
DIP START-OPEN= ON:
OPEN push (N.O.).
DIP PED-CLOSE= OFF:
PEDESTRIAN input (N.O.). Activation only takes place on
motor 2 for the Pedestrian operation time, if the opening
cycle has started (not from pedestrian function), the pe-
destrian control is considered as a START control.
DIP PED-CLOSE= ON:
CLOSE input (N.O.).
Antenna input for integrated radio-receiver board
(31: SIGNAL. 32: BRAID)
programmer.
ENGLISh
~
±10% 50Hz*
~
3W max
~
(0.2A max absorption)
universal palmtop
11
ALTAIR-P - Ver. 03 -