Maintenance And Inspection; Cold Weather Care - Interchange NSR83-21 Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

NSR83-21
NSC83-28
NSC83-34
14
OPERATING THE NAILER
(Options for all tool models)

MAINTENANCE AND INSPECTION

ƒ Disconnect air hose.
ƒ Clean the magazine. Remove dust and other debris
that may have accumulated in the magazine.
ƒ Lubricate the nail rail with tool oil.
1
ƒ Check that the nail feeder slides smoothly by pulling
it with your finger. If it does not slide smoothly, nails
1
can be driven at an irregular angle and injury may
occur.
ƒ In case of frequent jams, contact an authorized
service center.
A QUALIFIED PERSON SHOULD PERFORM
REPAIRS AND MAINTENANCE.

COLD WEATHER CARE

ƒ Do not store the tool in a cold weather environment.
Keep the tool in a warm area until beginning the
work.
ƒ If the tool is already cold, bring it in a warm area and
allow the tool to warm up before use.
1. Reduce the air pressure to 60 to 80 psi
(4.2 bar 4.2 kgf/cm2).
2. Remove all fasteners from the tool.
3. Connect the air hose and free-fire (blank-fire) the tool.
The lowered air pressure will be enough to free-fire
the tool.
Slow speed operation tends to warm up the moving
part.
Interchange Brands Framing Nailers: Operator's Manual

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Nsc83-28Nsc83-34

Table des Matières