WARNING
USE ONLY METAL DUCT 4" DIAMETER (102 mm
FOR CANADA). DO NOT USE DUCT LONGER THAN
SPECIFIED IN THE EXHAUST LENGTH TABLE.
Ducting longer than 150 equivalent feet will:
• Increase the drying times and the energy cost.
• Reduce the dryer life.
• Accumulate lint, creating a potential fire hazard.
• Total length of flexible metal duct shall not exceed
7.9' (2.4 m).
EXAMPLE ONLY
The following chart describes an example of one
possible ductwork installation.
DUCT PIECES
Less Than 4 Ft.
4≤
(10.2 cm)
Installation Instructions
EQUIVALENT
RIGID
LENGTH
Rigid Metal
1 Ft.
Ducting
(Preferred)
Elbows
10 Ft.
(90°/45°)
Turns Less
2 Ft.
Than 4 Ft.
Rigid Ducting
1 Ft.
4" Wall Cap
5 Ft.
TOTAL MUST BE LESS THAN OR EQUAL TO 150 FT.
The correct exhaust installation is your
responsibility.
Problems due to incorrect installation are not
covered by the warranty.
The length of the exhaust system depends upon
the type of duct, number of turns and the type of
exhaust hood (wall cap), and all conditions noted
below.
For satisfactory air movement, the total duct length
should not exceed 150 equivalent feet.
NUMBER
X
USED
X
(4)
X
(3)
X
(1)
X
(5)
X
(1)
Total Ductwork Length
25
EQUIVALENT
=
LENGTH
=
4 Ft.
=
30 Ft.
=
2 Ft.
=
5 Ft.
=
5 Ft.
=
46 Ft.