Battery Charger; Usage Instructions - ELCA GENIO-SFERA.E Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Multi_ING_Man_GenioSFERAE_03
GENIO-SFERA.E Radio remote control system
have tension at the "Functions Common" terminal when the receiver is active. This is done to easily power the
commons of all the other relays. The "Functions Common" output is protected by a fuse.
Note: The functions common of AR GENIO-FLEXI-SW.E receivers is usually already connected to the commons of
all the relays.
The Timed Stop function, in devices where it is present, makes it possible to activate the relative relay for approx.
15 seconds after the Stop function has been activated. This function is normally used to switch off explosion
motors.
5.2 RECEIVER COMMAND LAYOUT
ANNEX A
5.3 RECEIVER WIRING DIAGRAM
ANNEX B

6. BATTERY CHARGER

6.1 USAGE INSTRUCTIONS

Remember that for an optimal use of the NiCd and NiMH battery, you have to recharge it only when it is
completely discharged (that is, when the transmission and checking led, placed on the transmitting unit,
starts flashing quickly).
The battery charge must be done in a ambient temperature between +5°C and +35° C.
The battery shall be removed only when the transmitting unit is switched OFF.
Insert the exhausted battery into the provided battery charger. When the battery charger is powered the green light
(POWER) shall be ON.
When an exhausted battery is inserted into the battery charger the yellow light (CHARGE) shall switch ON indicating
that the battery is being charged. When the battery is fully charged the yellow light (CHARGE) shall switch OFF.
The complete recharging phase lasts max. 3 hours.
The CONTROL battery charger is provided with a pre-charge control system that will detect when the battery is fully
charged, stop the recharging process and ensure that the battery does not ruin quickly because of the improper
charging.
The pre-charge control system will also detect at any time the battery conditions. In case the battery is defective, the
yellow light (CHARGE) will be flashing continuously.
- Page 13 -

Publicité

Table des Matières
loading

Table des Matières