If the safety thermostat is tripped, the appliance has
to be restored to the initial working conditions as fol-
lows.
1 - Allow the oil to cool to 30-40°C.
2 - Open the hatch (A).
3 - Press the button (B) of the safety thermostat
tripped to restore the gas supply.
Important
To identify the thermostat that has been
tripped, check which burner has cut out
and press the corresponding button.
If the appliance is to be out of use for a lengthy pe-
riod, proceed as follows.
1 - Turn off the gas supply tap.
2 - Clean the appliance and the surrounding
areas thoroughly.
To ensure correct use of the appliance, the fol-
lowing rules should be adopted.
– Use only the accessories recommended by
the constructor.
– Use the baskets as appropriate.
– Before filling the well, check that the drain tap (A)
IT
IT
is turned off.
– Check that the oil level never drops underneath
the minimum level marked (B).
GB
GB
– Use single-seed oils or blends of oils specially
recommended for fryers.
DE
DE
– Melt solid fats in a separate container to avoid
damaging the appliance.
– Do not use the appliance until the oil is at working
FR
FR
temperature.
– Lower the basket slowly to prevent foaming.
ES
ES
– Filter the frying oil often to remove working resi-
dues.
Important
Store frying oil in the dark and filter it often
to slow down its gradual degradation. The
use of degraded oil for frying constitutes a
health hazard.
– Never use the appliance with no oil in the well, as
this may damage its structure.
– Use the basket hanger support to drain the foods
fried.
English

RESETTING THE APPLIANCE

LENGTHY DOWNTIMES OF APPLIANCE

USEFUL ADVICE FOR USE
B
B
3 - Spread a film of edible oil over the stainless
steel surfaces.
4 - Carry out all the servicing procedures.
5 - Leave the appliance uncovered and the cook-
ing chambers open.
A
– If the appliance is to be out of use for a short time,
reduce the oil temperature to the minimum level
or switch off the appliance to prevent unneces-
sary gas consumption and ageing of the oil.
– Change the oil when it fumes between 160-
180°C or when it becomes dark in colour.
– Use a polarimeter regularly to measure the per-
centage of polarised compounds.
– The recommended batch load is 0,9 kg for single
well.
- 10 -