Fitting a dustbag (dia. 32)
 Fit the new dustbag into the holder as
far as it will go. Leave the dustbag
folded up when you take it out of the
box.
 Close the dust compartment lid se-
curely, making sure it clicks into posi-
tion. Take care not to trap the dust-
bag when doing so.
A safety device prevents the lid clos-
ing without a dustbag in place. Do
not force it.
 Insert the hose connector into the
suction opening on the vacuum
cleaner until it clicks into position. To
do this, line up the guides on the two
pieces (dia. 01).

Replacing the motor protection filter

(dia. 33)
Replace the motor protection filter
whenever you start a new packet of
dustbags.
Every packet of original Miele dustbags
contains a motor protection filter. Mul-
tipacks contain four motor protection
filters (available depending on country).
 Open the dust compartment lid.
 Pull the dustbag out by the grip on
the collar.
 Lift up the filter frame until it clicks
and remove the old filter. Hold by the
clean, unsoiled section to remove it.
 Replace with a new motor protection
filter.
 Close the filter frame.
 Fit the dustbag into the holder as far
as it will go.
44
 Close the dust compartment lid se-
curely, making sure it clicks into posi-
tion. Take care not to trap the dust-
bag when doing so.

Replacing the exhaust filter

Depending on the model, your vacuum
cleaner will be fitted as standard with
one of the following exhaust filters (dia.
08).
a AirClean
Replace this filter every time you start a
new packet of Miele dustbags. Every
packet of original Miele dustbags con-
tains one AirClean exhaust filter. Mul-
tipacks contain four AirClean filters
(available depending on country).
b AirClean Plus 50 (light blue)
Replace this filter after approx. one
year. Make a note of the date on the fil-
ter.
c Active AirClean 50 (black)
d HEPA AirClean 50 (white)
Replace this filter when the exhaust fil-
ter timestrip® change indicator is com-
pletely red (dia. 13). The indicator lights
up after approximately 50 hours of op-
eration, which is equivalent to about a
year of average use. You can continue
vacuuming when the light comes on.
However, the suction power will be re-
duced as will the effectiveness of the fil-
ter if it is not replaced in good time.
Replacing the AirClean exhaust
filter (dia. 34 + 35)
Do not use more than one exhaust fil-
ter at a time.
 Open the dust compartment lid.
 Open the filter grille.