8 | English

Noise/vibration information

Typically, the A-weighted sound pressure level of the power
tool is less than 70 dB(A).
Vibration total values a
(triax vector sum) and uncertainty K:
h
2
2
a
≤2.5 m/s
, K=1.5 m/s
.
h
Operation

Starting Operation

Pay attention to the mains voltage. The voltage of the
u
power source must match the voltage specified on the
rating plate of the power tool.
Creation of Smoke During Initial Use
A coating protects the metal surfaces from corrosion ex-
works. This protective layer evaporates during initial use.
Switching On
Slide the on/off switch (4) upwards.
Thermal protection shutdown: If the power tool overheats
(e.g. due to a build-up of air), the heating system will auto-
matically switch off, though the blower will continue to run.
Once the power tool has cooled back down to its operating
temperature, the heating system will automatically switch on
again.
Switching Off
Slide the on/off switch (4) downwards into the 0 position.
After working at high temperatures for a prolonged
u
period, let the power tool cool down before switching
it off. To do this, allow it to run on the lowest temper-
ature setting for a short while.
Regulating airflow (GHG 20-63)
With the on/off switch (4), you can set the airflow to one of
several different levels:
Airflow setting
The specifications apply to a rated voltage [U] of 230 V. These spe-
cifications may vary at different voltages and in country-specific mod-
els.
Reduce the airflow, for instance, if the area surrounding a
workpiece cannot tolerate excessive heat or if a workpiece is
light enough that the airflow might move it.
Regulating temperature (GHG 20-63)
On the lowest airflow setting, the temperature is set to
50 °C. In the other two airflow settings, the temperature can
be adjusted.
When switching from the lowest airflow setting to another
setting, the temperature last set is called up again.
To increase the temperature, press "+" on the (12) button;
to decrease the temperature, press "–".
Briefly pressing the (12) button increases or decreases the
temperature by 10 °C. Pressing and holding down the button
1 609 92A 4RE | (26.10.2018)
l/min
°C
150
50
150–300
50–630
300–500
50–630
continuously increases or decreases the temperature by
10 °C until the button is released or the maximum/minimum
temperature is reached.
The set target temperature is shown in the display for three
seconds. The actual temperature at the nozzle output is dis-
played and the unit of measure for the temperature (6)
flashes until the target temperature is reached. The unit of
measure for the temperature stops flashing once the target
temperature is reached.
If you reduce the temperature, it takes a little while
u
for the power tool to cool down.
The lowest airflow setting is suitable for cooling down a
heated workpiece or for drying paint. It is also suitable for
cooling down the power tool before putting it down or chan-
ging the attachment nozzles.
Regulating airflow (GHG 23-66)
In switch position 1 on the on/off switch (4), you can adjust
the airflow in ten increments between 150 and 300 l/min. In
switch position 2, you can adjust the airflow in ten incre-
ments between 150 and 500 l/min.
Alternatively, you can use airflow/temperature combinations
that have been stored in the memory, (see "Saving airflow/
temperature combinations (GHG 23-66)", page 9).
The set airflow is displayed with the ten bar segments (9) at
the lower edge of the display.
Switch position
l/min
1
150–300
2
150–500
To adjust the airflow, first press the fan button (10). The fan
symbol (8) in the display flashes. Now you can adjust the air-
flow using the plus/minus button (12).
To increase the airflow, press "+" on the (12) button; to de-
crease the airflow, press "–".
If you wish to adjust the temperature again using the plus/
minus button (12), press the fan button (10) again. The fan
symbol (8) in the display stops flashing.
If you move from switch position 1 to position 2, the airflow/
temperature combination last used in position 2 is set.
Reduce the airflow, for instance, if the area surrounding a
workpiece cannot tolerate excessive heat or if a workpiece is
light enough that the airflow might move it.
Regulating temperature (GHG 23-66)
In switch position 1 on the on/off switch (4), the temperat-
ure is fixed at 50 °C. In switch position 2, you can adjust the
temperature between 50 and 650 °C.
Alternatively, you can use airflow/temperature combinations
that have been stored in the memory, (see "Saving airflow/
temperature combinations (GHG 23-66)", page 9).
The set temperature is shown in the display (13).
°C
50
50–650
Bosch Power Tools