Frame Of Information On The Network Configuration; Keep Alive Frame - ADEUNIS LoRaWAN US902-928 Pulse Guide Utilisateur

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

LoRaWAN US902-928 Pulse - Guide utilisateur / User guide version V1.0.0
Description of the frame:
Bytes 2 and 3 : register 330, number of daily periods under leak threshold (channel A)
Bytes 4 and 5 : register 331, number of daily periods under leak threshold (channel B)
In the example in grey this gives:
Bytes 2 and 3 : S330=0x0003, number of daily periods under leak threshold for channel A is set to 3
Bytes 4 and 5 : S331=0x0005, number of daily periods under leak threshold for channel B is set to 5
FR

4.1.3 Frame of information on the network configuration

Following reception of a downlink frame with the code 0x02 or on switching to the operating mode (from the Park or Command Mode), the
next frame (0x20) representing the network confguration of the product is transmitted:
0
EN
Code
0x20
0x20
Its size is of 4 bytes.
Description of the frame:
Byte 2 : register S220 : Activation of Adaptative Data Rate
Byte 3 : register S221 : connexion mode
In the example in grey this gives:
Byte 2=0x05 : Adaptative Data Rate is activated
Byte 3=0x01 : connexion mode is OTAA

4.1.4 Keep Alive frame

This frame (0x30) is trasmitted 24 hours after the startup of the application or after the transmission of the previous Keep Alive frame. In TEST
mode, this frame is transmitted every 5 minutes.
0
Code
0x30
0x30
Its size is of 11 bytes.
Description of the frame:
Byte 2 : Alarms state (bit to 1 if the alarm is activated else 0) :
Bit 0 – Exceeding flow on channel A
Bit 1 – Exceeding flow on channel B
Bit 2 – Tamper detected on channel A
Bit 3 – Tamper detected on channel B
Bit 4 – Leak detected on channel A
Bit 5 – Leak detected on channel B
Bit 6/7 – Reserved
Bytes 3 to 4 : maximum measured flow on channel A within the last 24 hours.
Bytes 5 to 6 : maximum measured flow on channel B within the last 24 hours.
Bytes 7 to 8 : minimum measured flow on channel A within the last 24 hours.
Bytes 9 to 10 : minimum measured flow on channel B within the last 24 hours.
1
Status
Cf Status
S220
0xA3
0x05
1
2
Status
Cf Status
Alarms
0xA3
0x19
2
3
PAYLOAD
S221
0x01
3 - 4
PAYLOAD
Max flow - chan-
Max flow - chan-
nel A
0x310A
5 - 6
7 - 8
Min flow - chan-
nel B
nel A
0x12C4
0x0010
9 - 10
Min flow -
channel B
0x0000
Page
80
of 100

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Arf8230b

Table des Matières