9.5 EVENT LIST (alarm protocol)
If the submenu "EVENT LIST" is selected, shortly
press the button "Set/AUTO" to call it.
EVENT LIST:
NO CH A/L/M DD-MM-YY HH:MM:SS
01
1
A
22-01-07 20:15:13
02
4
L
19-01-07 15:21:40
03
3
A
06-01-07 03:39:28
04
4
M
05-01-07 01:03:34
In this menu the last 20 alarm events are listed on two
menu pages, consecutively numbered and arranged
according to the time they occurred. It is possible to
change between the pages with the buttons
and
.
After the respective list number (column "NO") the fol-
lowing items are indicated:
– the channel concerned by the alarm (column "CH")
– the type of alarm (column "A/L/M"):
A = external alarm
L = loss of the video signal
M = alarm by the internal motion detector
– the date of the alarm (column "DD-MM-YY")
– the time of the alarm (column "HH:MM:SS")
To exit the submenu and to return to the main menu,
keep the button "Set/AUTO" pressed for 2 seconds.
9.6 AUTO SEQUENCE
(adjustments for the sequential switching)
If the submenu "AUTO SEQUENCE" is selected,
shortly press the button "Set/AUTO" to call it.
AUTO SEQUENCE:
CH1 : ON
CH2 : ON
CH3 : ON
CH4 : ON
QUAD : ON
TIME : 05 SEC
In this menu each camera channel and the quad pic-
ture for the sequential switching (→ chapter 7.3) can
be switched ON or OFF. In the line "TIME" the picture
dwell time (1 – 99 seconds) can be adjusted.
Select the respective line with the button
make the adjustment with the button
To exit the submenu and to return to the main menu,
keep the button "Set/AUTO" pressed for 2 seconds.
14
(PAGE1)
, , ,
or
or
.
9.7 OTHER
(alarm adjustments, adjustments for mirror-inverted
display of the picture and for reproduction of the
quad picture)
If the submenu "OTHER" is selected, shortly press the
button "Set/AUTO" to call it.
OTHER:
1.BUZZER:
LOSS : 05 SEC
MOTION : 05 SEC
ALARM : 05 SEC
2.MIRROR: CH1 : OFF
CH2 : OFF
CH3 : OFF
CH4 : OFF
3.BORDER : WHITE
Via the first menu item "BUZZER" it is possible to
adjust separately for the three alarm types how the
quad processor responds to an alarm triggering (also
see chapter 10 "Alarm functions"):
– line "LOSS"
For an alarm signal to sound in case of signal loss at
one of the camera inputs (6), adjust the time of the
alarm sound (1 – 99 seconds) in the line.
If no alarm signal is to sound in case of loss of a
video signal, set the line to "OFF".
– line "MOTION"
For an alarm signal to sound in case of alarm trigger -
ing by the internal motion detector and the alarm
relay to respond, adjust the alarm time (1 – 99
seconds) in this line. After the alarm time has ex -
pired, the alarm buzzer is switched off and the alarm
relay is reset.
If neither the buzzer nor the relay is to respond in
case of alarm triggering by the internal motion detec-
tor, set the line to "OFF".
– line "ALARM"
For an alarm signal to sound in case of alarm trigger -
ing by a connected alarm sensor and the alarm relay
to respond, adjust the alarm time (1 – 99 seconds) in
this line. After the alarm time has expired, the alarm
buzzer is switched off and the alarm relay is reset.
If neither the buzzer nor the relay is to respond in
case of external alarm, set the line to "OFF".
and
Via the second menu item "MIRROR" a mirror-inverted
display of the picture can be switched ON for each
camera channel.
Via the third menu item "BORDER" it can be selected
how the quad picture appears on the screen:
– "WHITE": white separating lines between the four
camera pictures
– "BLACK": black separating lines between the four
camera pictures
– "OFF": no separating lines between the four camera
pictures
Select the respective line with the button
make the adjustment with the button
To exit the submenu and to return to the main menu,