• Do not point the high-pressure jet towards materials, which contain asbestos or other harmful substances.
• Do not use the water cleaner in the rain.
• Pay particular attention to the instructions in the "Checks and connection to the mains electricity supply"
section.
• Pay particular attention to the instructions in the "Use with detergents" section.
• When the water cleaner is not in use, do not leave its plug in the power outlet and disconnect it before any activity.
More precisely, make sure that the mains switch (2) is in position "0", remove the plug from the power outlet,
press the lever (26) on the cleaner gun to eliminate any remaining pressure and bring the safety catch in its locked
position (25) (Fig. 4 - position S):
- before leaving the high power cleaner unattended, even for only a short time;
- after use;
In addition, wait until the high pressure cleaner has completely cooled down before cleaning or maintenance.
• During use, do not lock the lever (26) on the cleaner gun in the open position.
• Do not remove the plug from the power outlet by pulling on the power supply cable.
• Do not put any reducers or adaptors between the electric plug and the power outlet.
• Keep the power supply cable, any extension cords, the plugs and the outlets dry. Do not touch them with wet
hands.
• If the supply cord is damaged, it must be replaced by the Manufacturer or by a Skilled Technician, in order to
avoid a hazard.
• Do not cover the high pressure cleaner during operation and do not place it where there is inadequate
ventilation.
• When the high pressure cleaner is used in enclosed spaces, make sure that there is adequate ventilation.
5.1 h
andlInG
• When handling the high-pressure cleaner, use the handling bar (3) as shown in Fig. 5 operation M.
• Use the lifting handle (10) for lifting Fig. 5 operation N.
WArnIng
• Do not use the handling bar (3) to lift up the high-pressure cleaner.
5.2 p
relImInary
• Unroll the high-pressure pipe (23) completely.
• Attach a supply pipe to the water inlet's quick connection (12) using a normal garden connector. Step e - fig. 3.
• Open the tap to the water supply and make sure that there are no drips. Step f - fig. 3.
• Make sure that the main switch (2) is in the off position (the "0" position) and put the plug into the electric current
outlet. Step g - fig. 3.
• Push the main switch (2) to position "1".
• Press the cleaner gun's control lever (26) and wait for a continuous jet of water to be issued.
• Put the main switch (2) to position "0" and connect up the lance hose (28) and the spray gun (14), securing it tightly.
Step b in fig. 3.
5.3 s
o
tandard
• Restart the high pressure cleaner by turning the main switch (2) to position "1".
note: during this restart phase, the high pressure cleaner will immediately stop operating after the initial peak, as
the Total Stop device will take effect.
• Use the cleaner gun's lever (26) to start operation of the high pressure cleaner and thus start cleaning.
• You can alter the angle of the jet by adjusting the head (27) (Fig. 4 - Positions a and b).
5.4 u
d
se
WIth
WArnIng
• The high pressure cleaner was designed to be used with the detergents recommended by the Manufacturer. Use
of other detergents or chemicals can affect the safety of the high pressure cleaner.
Never suck up liquids, which contain solvents, petrol, diluents, acetone and fuel oil, as these products are highly
inflammable, explosive and toxic when nebulized.
• Carefully read the instructions and warnings on the label of the detergent to be used.
• Store detergents in a safe place out of children's reach.
• Should detergent come into contact with your eyes, wash immediately with water. Contact a doctor without delay