Introduction; Intended Use; Indications For Use; Contraindication - DeVilbiss Healthcare SleepCube DV53 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 44
If the system is placed on the floor, do not position it where it may be stepped on when getting out of bed.
CAUTION
The circular data port connector, located on the back of the SleepCube, is used to attach accessories to the device.
The connector must only be used with accessories approved for use by DeVilbiss. Do not attempt to attach any other
device to this connector, as it may damage the CPAP or the accessory device.
Never rinse or place the device in water. Never allow liquids to get into or around any of the ports, switches or air
filter. Doing so will result in device damage. If this occurs, discontinue use and remove the power cord from the
power source. Allow the device to completely dry before use.
Do not place the SleepCube where it can be knocked onto the floor, or where the power cord may create a tripping
hazard.
Only the DeVilbiss DV5 series Heated Humidifier system is recommended for use with the SleepCube. Other
humidifier systems may prevent the device from detecting snoring and may cause inappropriate pressure levels in
the mask.
Empty and dry humidifier water chamber before transporting.

INTRODUCTION

Intended Use

The DeVilbiss SleepCube Model DV53 Series Standard Plus CPAP is intended for use in treating OSA in spontaneously
breathing patients 30 Kg (66 lbs) and above by means of application of positive air pressure. The Device is to be used in
home and clinical environments.
Indications For Use (Optional Heated Humidifier)
Use on the advice and prescription of a licensed physician to help relieve the symptoms of dryness of the throat, nasal
passages and the mouth, which are common with positive airway pressure therapy. This is especially true in dry climates
and during the cold season when humidity in the air is typically lower than at other times.
Essential Performance
Sleep Apnea Breathing Therapy Equipment is considered not to have essential performance.

Contraindication

Do not use SleepCube system if your upper airway has been bypassed.
NOTE–Symptoms of dryness of the throat, nasal passages and the mouth are common with positive airway pressure
therapy. The SleepCube features an optional humidifier system to help minimize these effects.

KEY FEATURES

DeVilbiss SleepCube Device
and B)
1.
Keypad/LCD Display (see Figure C)
2.
Air Supply Port on Back
3.
Air Supply Port on Bottom (for optional humidifier)
4.
Air Supply Port Plug
5.
Heater Power Connector (for optional humidifier)
6.
AC Power Connector
7.
DC Power Connector
8.
Data Port
9.
Power Cord (appropriate to your wall outlet) (not
shown)
10. Air Inlet Filter Opening
11
Connector Cover (not shown)

Keypad

(Figure C)
1.
On/Off
2.
Previous Item
3.
Next Item
4.
Delay
5.
Decrease Value
6.
Increase Value
7.
Heater Power LED (for optional humidifier)
Ask your equipment provider for information about other
DeVilbiss masks, equipment and accessories.
SE-DV53-1
(Page 2, Figures A-F)
(Figures A

Humidifier Cradle

1.
Heater plate
2.
Heater power connector
3.
Storage compartment for connector cover (on
bottom)
4.
Air supply port inlet
5.
Air supply port outlet
6.
Flow generator release button
7.
Flow generator locking tabs

Water Chamber

1.
Chamber lid
2.
Chamber base
3.
Heat transfer plate (on bottom)
4.
Sealing gasket
5.
Water level indicators (front and sides)
6.
Chamber release latch
7.
Chamber disassembly lever

Therapy Management System

1.
SmartLink
(optional)
®
(Figure D)
(Figure E)
(Figure F)
EN - 5

Publicité

Table des Matières
loading

Table des Matières