Technical data

6.1

Accuracy

The specifications are typical values at 24 V DC, and room
temperature, with a nominal length of 500 mm in
conjunction with the BTL5-P-3800-2, BTL5-P-4500-1,
BTL5-P-5500-2
BTL6-A-3800-2
1)
BTL5-F-2814-1S, BTL5-T-2814-1S, BTL5-M-2814-1S or
BTL5-N-2814-1S magnet.
The BTL is fully operational immediately, with full accuracy
after warm-up.
For special versions, other technical data may
apply.
Special versions are indicated by the suffix -SA
on the part label.
Resolution:
Position
adjustable via SDO
in increments of 5 µm
Movement speed
adjustable via SDO
in increments of 0.1 mm/s
Sampling rate f
Standard
Non-linearity
Hysteresis
Repeat accuracy
Temperature coefficient
2)
6.2

Ambient conditions

Ambient temperature
Storage temperature
Relative humidity
Shock rating
Continuous shock
as per EN 60068-2-27
4)
Vibration
per EN 60068-2-6
4)
Degree of protection per
IEC 60529 when threaded
together
www.balluff.com
, BTL6-A-3801-2
,
1)
1)
5 µm
0.1 mm/s
500 Hz
±30 µm
≤ 1 LSB
≤ 2 LSB
(6 µm + 5 ppm
x nominal length)/K
3)
−40 °C...+85 °C
−40 °C...+100 °C
< 90%, non-
condensing
100 g/6 ms
100 g/2 ms
12 g, 10 ...2000 Hz
IP67
6.3

Supply voltage (external)

Stabilized voltage
5)
Residual ripple
Current draw (at 24 V DC)
Inrush current
Reverse polarity protection
Overvoltage protection
Dielectric strength (GND to
housing)
6.4

Control signals

CAN_L, CAN_H, CAN_GND in accordance with
CiA
 DS 301.
®
6.5

Magnet

Max. number of magnets
6.6

Dimensions, weights

Nominal length
Weight (depends on length)
Housing material
In the position range 0 to 20 mm, the specified linearity limit can be
1)
exceeded by ±100 µm.
Nominal length 500 mm, magnet in the middle of the measuring range
2)
3)
For
: Use in enclosed spaces and up to a height of 2000 m above sea
level.
4)
Individual specifications as per Balluff factory standard, resonant
frequencies excluded
For
: The BTL must be externally connected via a limited-energy
5)
circuit as defined in UL 61010-1, a low-power source as defined in
UL 60950-1 or a class 2 power supply as defined in UL 1310 or UL 1585.
Number dependent on nominal length (see section 3.3)
6)
20...28 V DC
24 V ± 2 V
SS
≤ 100 mA
≤ 3 A
yes
yes
500 V DC
4
6)
50...4000 mm
Approx. 1,4 kg/m
Aluminum
english