TECHNICAL SPECIFICATIONS
Model
Cooling Capacity (Btu/h)/ W
Heating Capacity (Btu/h)/ W
Dehumidifying Capacity (l/h)
Standard Cooling Input Power/Current
Heating Input Power/Current
Air Flow Volume (m³/h)
Rated Voltage /Frequenc(V/Hz)
Sound Pressure Level (dB (A))
Rated Energy Efficiency Ratio (EERrated)
Rated Coefficient Of Performance (COPrated)
Global Warming Potential (kg CO )
EER /COP Class
Net Weight (Kg)
Dimensions W X D X H
Refrigerant
Applying Space (m²)
Fuse
IP protection level
Dimension of the condensation water outlets
DISPOSAL
Appliances, accessories and packaging must be recycled in an environmentally respon-
sible manner. Electrical appliances which are not longer serviceable can be returned
to retailers for recycling. Do not include electrical appliances in domestic rubbish. As
required by EU Directive 2002/96/EC on Waste Electrical and Electronic Equipment as well as
legislation enacting this into national law, electrical equipment which is no longer serviceable
must be collected separately and recycled in an environmentally responsible manner.
MFPH32-1280
12.000 Btu/h / 3500 W
12.000 Btu/h / 3500 W
1.8 l/h
1200 W/5,2 A
1150 W/5,0 A
400 m3/h
220-240 V~/50 Hz
LPA ≤55 dB (A), LWA≤65 dB (A)
2,6
2,4
2100
A / A
29.5 kg
400 x 387 x 794 mm
R410A
24 - 29 m2
3,15 A / 250 V ø5 x L 20 mm
IP X0
15 mm
TROUBLESHOOTING
The following cases may not always be a malfunction. Please check suggestions below before
asking for service.
Failures
Analysis
Does not run
• If the protector trip or fuse is blown.
• Please wait for 3 minutes and start again, protector device may be
preventing unit from working.
• If batteries in the remote controller are exhausted.
• If the plug is not plugged in properly.
Runs for a short
• If the set temperature is close to room temperature, you can lower
while only
the set temperature.
• Air outlet is blocked by obstacle. Take the obstacle away.
Runs but no cooling
• If the door or window is open.
• If there is another appliance heat-working like heater or lamp etc.
• The air filter is dirty, please clean it.
• Air outlet or intake is blocked.
• Set temperature is too high.
Water leak during
• Drain the condensate before moving.
moving
• To avoid water leakage, please locate the unit on flat ground.
Does not run and
• Pull out the rubber plug to drain water.
water full indicator
• If it is often in this state, please contact qualified service centre.
„E4"
52 53