Power-Fail Time; Factory-Defaults; Set Nominal Values; Setting Temperature And Dwell Time - BEHAbelt PPuls HP01 Mode D'emploi

Masquer les pouces Voir aussi pour PPuls HP01:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

2.2.5.4 Power-fail time:

It is possible to define a period during which an ongoing welding process is automatically con-
tinued after a power outage. The period can be set from 0s to 30s. In case of a power outage
during the welding process and if the power comes back within the set time, the interrupted
process will automatically be continued where it stopped at the time of the power outage.
Press key [6]
pressing key [6]
entered digit by pressing key [5]
to return to the previous menu level.
Please note:
When an ongoing process is continued after a short term power outage the command data-
base is tested after the end of the process and before returning to standby-mode.

2.2.5.5 Factory-defaults:

It is possible to reset the controller to default settings (as delivered). This means that all
user-specific settings as well as any recipe and log data (only Xpert versions) you saved
will be lost.
Press key [6]
reset the controller to default settings. Confirm by pressing key [6]
is now back to delivery status.
It is possible to discontinue the action by pressing key [5]
this menu item and to return to the previous menu level.
3

Set nominal values

Set welding temperature and dwell time with temperature and time setting key [1]
parameters are decisive for the connection and have to be adjusted for each application, belt,
and connection type.
Ensure that the parameters are set correctly, in order to achieve optimum results. Wrongly
welded belts my cause damage and may jeopardize persons and machines.
3.1

Setting temperature and Dwell time

Press temperature and time setting key [1]
left the display shows the welding temperature of the upper heating platen and at the lower
left the welding temperature of the lower heating platen and at the lower right the dwell time.
After pressing the temperature and time setting key [1]
temperature of the upper platen starts flashing. Use key [5]
40
long (>1s) to change settings. Enter desired value and confirm by briefly
. You can cancel the entry by pressing key [5]
long to reset the controller. You will again be asked if you really want to
briefly. Use key [5]
briefly to display set values. At the upper
long or delete the last
to leave this menu item and
briefly. The system
. Use key [5]
long (more than one second) the
to delete the last digit of the
to leave