Unpacking; Setup And Installation - AHT ATHEN Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

AHT Cooling Systems GmbH
►In event of damage, contact the
maintenance service (see → Chapter
10.5).
WARNING
Transport the device with floor trucks.
Risk of injury to persons during
collisions.
►Observe the transport routes for floor
trucks.
►Secure the cargo.
►Floor trucks must only be operated
by trained persons.
►Observe the details for the stacking
height on the packaging.
NOTE
• Material damage due to transport and storage.
►Do not expose the device during storage and
transport to temperatures higher than 70°C (158°F).
►Transport and store the device only in a type-based
stable operating position (horizontal alignment).
►If the device was still inclined during transport,
wait a minimum of 2 hours before commissioning.
►When being delivered, ensure continuous
accessibility up to the installation room. (Observe
the transit heights/widths/installation space height
and adequate shunting radii.)

6 Unpacking

Check the device for damage (bumps, scratches)
before and during unpacking. Contact the maintenance
service in case of damage (see → 10.5).
WARNING
Disposal of packaging material and
films. Danger of suffocation.
►Keep packaging material and foils
away from children.
►Do not let children play with them.
WARNING
For devices of type R-290: Damage to the
refrigerant circuit. The refrigerant can
escape and create an explosive gas/air
mixture. Risk of fire.
►Ensure good ventilation.
►Observe the safety and warning
information for devices with flammable
refrigerants (see → Chapter 1.6.2.1).
►In event of damage, contact the
maintenance service (see → Chapter
10.5).
Heavy device parts. Hands can be
jammed.
►When unpacking, pay attention to
fingers and hands.
►Wear protective gloves.
on18.05.2018 11:08
CAUTION
361929_0917_BA_SM_V4_06.09.2017_U_enUS_DRUCK.docx
NOTE
• Material and property damage due to missing
parts of the device.
►Check for loose parts in the packaging. ►Do not
dispose of loose parts. If it cannot be determined
where the loose parts belong, check with the
maintenance service (see→ Chapter 10.5).

7 Setup and installation

The operating company can set up and install the device.
For technical data for interfaces, see → 2.2.
Technical modifications to the device can only occur
with the coordination and approval of the
manufacturer.
NOTE
Material and property damage due to congestion of
the warm exhaust air (heat accumulation).
►The exhaust air must be able to escape freely to
the rear side.
►Minimum distance with separate installation
All round: 100 mm
►Minimum distance with block installation (see → Fig. 5.)
A= 0 mm
B= 100 mm / 155 mm (device-specific)
Fig. 5: Minimum distances with block installation
With the block installation, the ventilation openings
on the device cover must not be blocked.
►Superstructures can be attached only in agreement
with the manufacturer.
Minimum distance 100 mm.
The devices may be connected using bus cables (see
→ Chapter 4.2.2.3, 4.2.3.3).
The temperature display, safety instructions and
power rating plate (see → Chapter 2.2.1) must
always be kept clear.
WARNING
Danger of tilting of the device. People's
bodies can be jammed.
►Remove the transport pallet only when the
stable, final installation position has been
reached. If you have questions, contact the
maintenance service (see → Chapter 10.5).
►Do not climb onto or into the device.
Page 46