Télécharger Imprimer la page

T21 - T31 ( Pag. 54) - Telcoma Automations T21 Instructions D'utilisation

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 14
GB
INSTRUCTIONS FOR INSTALLATION AND PROGRAMMING
This handbook is aimed at qualified technical installation personnel
Carefully read all instructions in this handbookbeforeinstallation.
Improper use of the producto rincorrect connections could impair correct operation of the unit and safety
of the final user
T21 CHARACTERISTICS
This control unit is suitable for the automation of:
- rolling gates and roller shutters with limit switches incorporated in the motor
- simple automations with 230V motor
The control unit is equipped with:
- work and pause time self-learning function
- automatic re-closing function (disableable)
- connectors for OC receivers
- Step-by-Step and Pedestrian control inputs
- Stop and Photocell safety inputs
- NC edge or balanced input (NO contact and 8.2K resistor)
- 24Vac output for auxiliary circuits (PTC protection)
- 230V motor output
- 230V flashing light output
T31 CHARACTERISTICS
This control unit is suitable for the automation of:
- rolling gates and roller shutters with limit switches incorporated in the motor
- rolling gates and roller shutters with external limit switches
- simple automations with 230V motor
The control unit has the same features as model T21, with the addition of:
- Motor torque adjustment
- limit switch inputs
- output for 230 V courtesy light
TECHNICAL DATA
Electrical parameters:
Power supply
Frequency
Stand-by input (230V)
Maximum input (230V)
Max. motor power 230V
Working temperature
Card size (W x H x D)
34
U.M.
Vac
Hz
mA
A
VA
°C
mm
T21 - T31
230 ±10%
50
8/10 min/max
6,3
1000
-20 +60
148x103x57

Publicité

loading

Ce manuel est également adapté pour:

T31