<Viewing the Current Simple Timer Settings>
5
TIMER
1. Be sure that the simple timer indicator is visible on the screen (at 1).
2. Press the Timer Menu button b, so that the "TIMER MONITOR" appears on
the screen (at 5).
• If the ON or OFF simple timer is running, the current timer value will appear
at 6.
• If ON and OFF values have both been set, the two values appear
alternately.
3. Press the Mode (Return) button 2 to close the monitor display and return to
the standard control screen.
<To Turn Off the Simple Timer...>
Press the Timer On/Off button 9 so that the timer setting no longer appears on
the screen (at 7).
°C
<To Turn On the Simple Timer...>
Press the Timer On/Off button 9 so that the timer setting becomes visible at 7.
°C
Examples
If ON and OFF times have both been set at the simple timer, operation and
display are as indicated below.
Example 1:
Start the timer, with ON time set sooner than OFF time
ON Setting: 3 hours
OFF Setting: 7 hours
Hr
ON
AFTER
SIMPLE
Hr
AFTER
OFF
°C
°C
SIMPLE
SIMPLE
Example 2:
Start the timer, with OFF time is sooner than ON time
ON Setting: 5 hours
OFF Setting: 2 hours
Hr
AFTER
OFF
°C
°C
SIMPLE
Hr
ON
AFTER
SIMPLE
°C
°C
SIMPLE
6
Timer Setting
Hr
ON
AFTER
OFF
1
SIMPLE
7
°C
SIMPLE
7
Hr
ON
AFTER
°C
SIMPLE
At Timer Start
Display shows the timer's
ON setting (hours
remaining to ON).
Display changes to show
At 3 hours
the timer's OFF setting
after timer
(hours remaining to
start
OFF).
The time displayed is
OFF setting (7 hours) –
ON setting (3 hours) = 4
hours.
At 7 hours after
The air conditioner goes
off, and will remain off
timer start
until someone restarts it.
At Timer Start
Display shows the timer's
OFF setting (hours
remaining to OFF).
Display changes to show
At 2 hours
the timer's ON setting
after timer
(hours remaining to ON).
start
The time displayed is
ON setting (5 hours) –
OFF setting (2 hours) = 3
hours.
At 5 hours after
The air conditioner
comes on, and will
timer start
continue to run until
someone turns it off.
3 Using the Auto Off Timer
This timer begins countdown when the air conditioner starts, and shuts the air
conditioner off when the set time has elapsed.
Available settings run from 30 minutes to 4 hours, in 30-minute intervals.
Note:
*1 Weekly Timer/Simple Timer/Auto Off Timer cannot be used at the same time.
*2 The Auto Off timer will not operate when any of the following conditions is in
effect.
The timer is off; the system is in malfunction state; a test run is in progress; the
remote controller is undergoing self-check or remote controller check; the user
is in the process of selecting a function; the user is in the process of setting the
timer; the system is under central control. (Under these conditions, On/Off
operation is prohibited.)
AFTER
TEMP.
MENU
ON/OFF
BACK
MONITOR/SET
DAY
PAR-21MAA
CLOCK
2
a
9
<How to Set the Auto Off Timer>
2
AFTER
1. Be sure that you are at a standard control screen, and that the Auto Off timer
indicator is visible in the display (at 1).
When something other than the Auto Off Timer is displayed, set it to AUTO
OFF TIMER using the function selection of remote controller (see 3.4., [4]–3
(3)) timer function setting.
2. Hold down the Timer Menu button b for 3 seconds, so that the Set-Up
screen appears.
(Note that each press of the button toggles the display between Set-Up and
TIMER MONITOR.)
3. Press the appropriate Set Time button a as necessary to set the OFF time
(at 3).
4. Press the Filter
button 4 to lock in the setting.
Note:
Your entry will be cancelled if you press the Mode (Return) button 2 before
pressing the Filter
button 4.
5. Press the Mode (Return) button 2 to complete the setting procedure and
return to the standard control screen.
6. If the air conditioner is already running, the timer starts countdown
immediately. Be sure to check that the timer setting appears correctly on
the display.
<Checking the Current Auto Off Timer Setting>
4
TIMER
AFTER
1. Be sure that the "Auto Off" is visible on the screen (at 1).
2. Hold down the Timer Menu button b for 3 seconds, so that "TIMER
MONITOR" is indicated on the screen (at 4).
• The timer remaining to shutdown appears at 5.
3. To close the monitor and return to the standard control screen, press the
Mode (Return) button 2.
OFF
AUTO OFF
ON/OFF
b
FILTER
4
CHECK
TEST
OPERATION
CLEAR
3
Timer Setting
OFF
1
AUTO OFF
5
Timer Setting
OFF
1
AUTO OFF