Check the device for transport damage. If there is damage the retailer must be notified without delay, at the latest
however, within 8 days of the purchase date.

2. Safety measures

Attention! Use in garden ponds and the protected area of garden ponds is only permitted if the installation complies
with the valid regulations. Consult a qualified electrician.
Attention! Do not use the pump in or on swimming pools!
Prior to use:
Check the mains cable and plug for damage.
Mains voltage and current type must agree with the information on the type plate.
Only connect the pump via a residual current circuit breaker (RCCB, ∆ = 30 mA) to a proper earthing contact
socket outlet.
Install the connection socket outlet in the water-protected area and at least 2 m away from the edge of the pond.
Always protect the mains plug from moisture.
Unplug the mains plug before performing any work on the pump, fountain or pond.
Do not operate the pump if there are people in the water (disconnect the pump from the mains supply beforehand!)
Important! If there is damage to the mains cables or the motor housing the complete pump is unusable and must
be disposed of. Repair is not possible because the connecting cable is permanently cast in the motor housing.
Never suspend or transport the pump by the mains cable.
This pump is equipped with a permanent magnet, its magnetic fields can influence cardiac pacemakers,interfere
with electrical / electronic components and delete the data on data carriers.
People with cardiac pacemakers should always maintain a safety distance of at least 30 cm to the pump.

3. Application areas

This product is an immersion pump, the motor is completely cast in epoxy resin. The pump is designed for use in water,
such as: garden ponds, fish ponds, spray fountains, terrace fountains, indoor spray fountains, aquarium, as well as for
water aeration and circulation.
This product is intended for private use in the home area and not for commercial or industrial purposes.
The pump is not suitable for displacement of salt water, faecal matter, flammable, corrosive or other hazardous liquids.
The pumped liquid must not exceed the maximum temperature specified in the technical data.
Do not use the pump in or on swimming pools!

4. Technical data

Model
Mains voltage / frequency
Rated power
Degree of protection
pump inlet
pump outlet
1)
Max. flow rate (Q
)
max
Max. pressure
Max. delivery head (H
)
max
Max. immersion depth 
Maximum temperature of the pumped liquid (T
Weight
Dimensions (L x D x H)
Item no.
1)
The specified maximum capacities have been determined with a free, unreduced outlet.
8
1)
)
max
WP 500-10R
230 V~ / 50 Hz
6 Watt
IP68
15 mm
10,5 mm
500 l/h
0,1 bar
1 m
1 m
35 °C
~. 1 kg
8,5 x 5 x 6 cm
30014 / 30010