Winterizing The Ph First; Trouble-Shooting Guide; Alarms - Zodiac O'Clair pH First Notice De Montage Et D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

6

Trouble-shooting guide

Alarm
5.2.

Winterizing the pH First

• When the regulator has to be winterized, it is advisable to pump clean water
through it in order to rinse the peristaltic pipe.
Then, position the tablet holder on " 6:00 " using the self - priming function
and pressing the navigation button " up " (or by turning the tablet holder
clockwise).
These two precautions will make it easier to restart the appliance.
• Remove the pH sensor from its holder. Store it in its original flask
or a cup filled with tap water. If necessary plug sensor holder.
!
Note: never leave the end of the sensor out of water!
6.1.

Alarms

The left portion of the LCD screen on your pH First displays various
alarms (message flashing or fixed).
This makes it easy to identify the problem.
Cause
The container of corrective
solution is empty
First OFA step enabled
(time > 70 %)
Second OFA step enabled
(time = 100 %)
Filtration stopped
Buffer solution ineffective
PH sensor defective
Parameter error
Solution
• Replace the container
• Make sure that the white float on the intake
functions correctly
• Press " CAL / Enter "
to stop the alarm
• Press " CAL / Enter "
to stop the alarm
• Start filtration
• Check the connection
• Replace the buffer solutions
• Clean and /or replace the pH sensor
• Press "CAL/Enter" to cancel the fault
• Call your local pool professional
EN
35

Publicité

Table des Matières
loading

Table des Matières