Operating Advice; Calibration Procedure - Zodiac O'Clair pH First Notice De Montage Et D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

3

Operating advice

1
> Fill flask n°2 with clean water
(tap water).
Figure
1.
4
> Immerse the sensor
in flask n° 1 (pH 7).
Figure
4.
28
3.1.

Calibration procedure

Refer to paragraph 4.1. to change the language.
!
Important:
The sensor must be calibrated when your pH First is first installed and
ideally every two months there after.
> Calibration must be done each time your pool is restarted at the beginning
of the season.
> The procedure should be repeated if an abnormal amount of corrective solu-
tion is consumed (pH minus or pH plus).
> The calibration procedure can only be carried out when filtration is stopped.
> Before calibrating, stop filtration and close the valves so as to isolate the
pH sensor holder from flowing water.
2
> Undo the sensor holder and
remove the sensor from the pipe.
Figure
2.
5
a
b
3
> Rinse the sensor in flask n°2
(water).
Then shake gently to remove
excess water.
Figure
3.
c
> Keep the "CAL/Enter" button
pressed for more than 5 seconds
until " Calibration " appears on the
5a).
LCD screen
(Figure
Press the "CAL / Enter " button
again as indicated on the screen
for calibration on pH7
(Figure
an automatic progression bar then
appears
(Figure
5c). Keep the
sensor immersed in the buffer
solution for 30 seconds.
5b):