Type of calibration

Your pH First is calibrated by default in 2 steps: pH7 and pH4.
This can be done in one single step on pH7 (faster but with lower measure-
ment reliability over time).
To change it when in the " Program" menu, enable the option list by pressing
the "CAL/ Enter " button (a small arrow appears on the right of the screen and
the type of calibration flashes). Then select the type chosen using the "up "
and " down" navigation buttons.
Accept the choice by pressing the " CAL / Enter " button.
Note:
If calibration is done in one step, the procedure described in paragraph
3.1. will automatically stop at the end of calibration with solution 7.
4.7.

Detection that filtration is in progress

Your pH First is equipped by default with a double power feed for keeping
the appliance live in order to calibrate the pH sensor when filtration is stop-
ped.
However, it is possible to disable this function if the electrical connection
is different (work done by a professional).
!
Caution:
The pH First no longer takes into account whether filtration is in progress
and is likely to inject corrective solution when there is no flow in the
pipes. Disabling is only possible if the mains power cable is controlled
by the filtration.
To change this function when in the " Program" menu, enable the option list
by pressing the "CAL/ Enter " button (a small arrow appears on the right of the
screen and the status of detection of filtration flashes). Then select "ON " or
"OFF " using the "up" and "down" navigation buttons.
Accept the choice by pressing the "CAL / Enter " button.
4.8.

Resetting the appliance

In the event of incorrect manipulation, it is possible to restore all the original
pH First functional settings.
Procedure for resetting the pH
> Switch OFF the appliance.
> Switch ON the appliance by pressing simultaneously on the two " up " and
" down" navigation buttons (keep the buttons pressed until the message
appears on the screen).
> Select " Yes " or " No" using the navigation buttons, then accept using the
" CAL / Enter " button.
> All the factory settings will then be restored.