Digital Readout Module - WOHLHAUPTER VarioBore 536 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

English
3E Digital Readout Module
This precision boring tool can be operated
optionally with the electronic positioning
system with digital readout module.
Fig. 12
Fig. 13
Fig. 14
20
Please follow the sequence for setting the
diameter as set out below:
(Fig. 12, 13, 14):
1. Clean coupling and contact points on
tool and display unit
2. Clip display unit into holding grooves
provided in tool (positioning to match
contact points, Fig. 12)
3. Switch on the digital readout module by
operating the "ON/Reset" ① button.
The last displayed dimensional value ap-
pears on the display when it is switched
on. Automatic switch-off takes place
30 seconds after the end of the setting
procedure. Max. switch-on period 120
seconds.
4. Release threaded clamping pin ③
(Fig. 14).
5. Adjust the boring range with the adjust-
ing screw ② (Fig 12, 13) using a hexa-
gon wrench WAF 2.5 and reading-off the
display at the same time. The actually
set value for the diameter at the slider or
the cutting edge is displayed. Note the
following:
No preceding sign = diameter increase,
negative preceding sign (–) = diameter
reduction.
6. Tighten threaded clamping pin ③
(Fig. 14) (tightening torque 3 Nm
(26.55 in. lbs.))
7. Remove display unit from tool
Notes:
• When the display is switched on, this
can be reset to "0" by operating the
"ON/Reset" ① again.
• The difference from the previously set
value or 0 is always displayed. The abso-
lute slider position cannot be displayed.