SC TESSERA – ERROR MESSAGES AND PROTECTIVE FUNCTIONS
Over 10 second protection
If you press and hold the Fire button for more than 10 seconds, the unit will automatically switch off� The display
shows OVER 10 s�
Short circuit protection
f a short circuit occurs ATOMIZER SHORT appears on the display�
Resistance Too Low
If the coil resistance drops below 0�1 ohm in VW mode or in the selection of bypass, or below 0�05 ohm in tempera-
ture mode, the display will show ATOMIZER LOW�
No atomizer head detected
NO ATOMIZER will appear on the screen when no vaporizer is connected�
Surge Protection
If the voltage of the battery drops below 3�3 volts, the display will show BATTERY LOW and then LOCK� Charge the
battery to unlock the device�
Temperature Protection
When the coil reaches the set temperature in TC/TCR mode, the TEMP PROTECTION screen appears� You can
continue to use the device as usual�