Maintenance
Check for leaks again after maintenance work and/or replacement
of components.
4.1
Inspection and maintenance intervals
Dräger recommends the following inspection and maintenance
intervals. Observe national directives.
Type of work to be
performed
Check by the wearer
Visual inspection, function and
leak test
Cleaning and disinfection
Replace the exhalation valve disc
Replace speech diaphragm
1)
For air-tight packed full-face masks every 2 years.
2)
For air-tight packed full-face masks, otherwise every 6 months.
Panorama Nova P
X
1)
X
X
2)
X
X
X
X
(approved by Dekra Exam)
4.2
Cleaning and disinfection
Clean and disinfect the full-face mask after every use.
WARNING
!
The mask body must be thoroughly cleaned so that no
residues from skin care products remain on it.
Otherwise the elasticity in the sealing range can be lost and
the mask will no longer sit correctly.
Non-observance of this warning can cause poisoning or
death.
CAUTION
!
Do not use any solvents (e.g. acetone, alcohol) or cleaning
agents containing abrasive particles for cleaning and
disinfection. Use only the methods described and the listed
cleaning and disinfection agents. Other agents, dosages and
contact times may damage the product.
The undiluted agents are damaging to health if they come into
direct contact with the eyes or skin. For this reason, wear
safety goggles and protective gloves when working with
these agents.
Do not use a cloth to clean or dry the inside of full-face masks
with visors that are marked "PC/CC". This may damage the
coating. After drying, these masks should be aired unpacked
for at least one day under standard climatic conditions
according to DIN EN ISO 291, so that the coating can
regenerate and the optimum working life is achieved.