In Case Of Problem - Atlantic RSS 2012 500 W Notice D'installation Et D'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 3
Problems Encountered
The device does not heat - Ensure that the main circuit breakers are closed or that the overload
The device heats all the
time
The surface of the advice
is very hot.
The last elements, top and
bottom, are more tepid
than the rest of the advice
24h Auto mode does not
repeat every day.
The device does not fol-
low the programming
instructions
Repetition of 24h Auto
mode does not start at
the desired time.
I
N CASE OF PROBLEM
cut-out has not cut off the supply to the advice.
- Check the air temperature in the room.
- Check that the device is not located in a draft or that the tempera-
ture setting has not been changed.
- There may be a fluctuation in the electricity supply. If you experience
a problem (thermostat locked, ...), cut off the electricity supply to the
towel-dryer (via the fuse or circuit breaker) for approx. 10 minutes and
the switch it on again.
- If you encounter the same phenomenon frequently, have your power
supply checked by your local utility.
It is normal for the device to be hot when it is operating; the maximum
surface temperature is limited in accordance with the prevailing stan-
dard. If, nevertheless, you think your advice is always too hot, check that
the output is suitable for the size of your room (we recommend 50W /
m
3
) and that the advice is not located in a draft interfering with its auto-
matic controls. The last elements, top and bottom, are more tepid than
the rest of the advice
- In the case of the top one, the upper elements are not completely filled
to allow for expansion of the thermodynamic fluid. They heat up only
by conduction.
- In the case of the bottom one, the lower elements channel the return-
ing fluid after it has transmitted its heat.
- Check that the electricity supply has not been interrupted at any time.
The position of the mode selection wheel A may have been changed
(refer to the section on page 13).
- Ensure that the programmer is being used correctly (please refer to the
User's Manual).
- Check whether the electricity supply has been cut off at any time.
- Check whether there has been a changeover from Summer to Winter
time or vice versa.
15
Checks to be made