Télécharger Imprimer la page

BFT DEIMOS BT Instructions D'utilisation Et D'installation page 19

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 23
-
Slow-down closing motor torque (cls. t slow) [ 50% ]
(Advanced parameters ⇒ address 9)
Set the numerical value of the motor torque between 1% and 99%.
Fast Opening Time (op. speed. time) [ 15 s. ]
-
(Advanced parameters ⇒ address 6)
Set the time ato normal opening speed (not slowed down), ranging from
1 second to 2 mins.
-
Fast Closing Time (cls. speed. time) [ 15 s. ]
(Advanced parameters ⇒ address 7)
Set the time to normal closing speed (not slowed down), ranging from 1
second to 2 mins.
Note: The slow-down time, on closing and on opening, is obtained by
timing one manoeuvre, and setting a lower value within this parameter. If,
for example, one manoeuvre lasts 15 seconds, set "normal speed time"
to 12s to obtain 3s of slow-down time.
-
Slow-down speed (slov speed) [ 0 ]
(Advanced parameters ⇒ address 5)
Set the slow-down speed by choosing from one of the following values:
0 – slow down disabled
1 – slow down at 50% of normal speed
2 – slow down at 33% of normal speed
3 – slow down at 25% of normal speed
15.2) MENU LOGIQUES (logic)
-
TCA (TCA) [ OFF ]
ON
Activates automatic closing
OFF Excludes automatic closing
-
3 Steps (3 step) [ OFF ]
ON
Enables 3-step logic. A Start impulse has the following effects:
door closed:
opens
on opening:
stops and enters TCA (if configured)
door open:
closes
on closing:
stops and reopens
OFF Enables 4-step logic. A Start impulse has the following effects:
door closed: opens
on opening:
stops and enters TCA (if configured)
door open:
closes
on closing:
stops and does not enter TCA (stop)
after stopping: opens
-
Impulse lock (ibl open) [ OFF ]
ON
The Start impulse has no effect during the opening phase.
OFF The Start impulse becomes effective during the opening or closing phase.
-
Rapid closing (fast cls) [ OFF ]
ON
Closes the gate after photocell disengagement, before waiting for the
end of the TCA set.
OFF Command not entered.
-
Photocell test (test phot) [ OFF ]
(Advanced logics ⇒ address 14)
ON
Activates photocell check
OFF Deactivates photocell check
If this setting is not activated (OFF), it inhibits the photocell checking
function, allowing connection of devices not provided with additional
checking contact.
-
Gate-open or 2nd radio channel warning light (SCA 2ch) [ OFF ]
ON
The output between terminals 10 and 11 is configured as Gate-open
warning light, in this case the 2nd radio channel controls pedestrian
opening.
OFF The output between terminals 10 and 11 is configured as 2nd radio
channel.
-
Prealarm (preal) [ OFF ]
ON
The blinker comes on about 3s before the motors start.
OFF The blinker comes on at the same time as the motors start
-
Hold-to-run control (hold-to-run) [ OFF ]
ON
Hold-to-run operation: the manoeuvre continues as long as the control
key is kept pressed.(OPEN-CLOSE)
OFF Impulse operation, according to the 3 or 4 step logic.
-
Fixed code (fixed code) [ OFF ]
(Advanced logics fi address 13)
ON
The receiver is configured for operation in fixed-code mode, see
paragraph on "Radio Transmitter Cloning".
OFF The receiver is configured for operation in rolling-code mode, see
paragraph on "Radio Transmitter Cloning".
-
Radio transmitter programming (radio prog) [ ON ]
(Advanced logics fi address 15)
ON
This enables transmitter storage via radio:
1 – First press the hidden key (P1) and then the normal key (T1, T2,
T3 or T4) of a transmitter already memorised in standard mode by
means of the radio menu.
2 – Within 10s press the hidden key (P1) and the normal key (T1, T2,
T3 or T4) of a transmitter to be memorised.
The receiver exits the programming mode after 10s, other new trans-
mitters can be entered before the end of this time.
This mode does not require access to the control panel.
OFF This disables transmitter storage via radio.
The transmitters can only be memorised using the appropriate Radio menu.
INSTALLATION MANUAL
15.3) RADIO MENU (RADIO)
-
Add
Allows you to add one key of a radio control device to the receiver
memory; after storage it displays a message showing the receiver
number in the memory location (from 01 to 64).
-
Add Start button (add start)
associates the required key to Start command
-
Add 2ch button (add 2ch)
associates the required key to 2nd radio channel
For transmitters with hidden key, press hidden key P1 (fig. B1A). For
transmitters without hidden key, the key P1 function corresponds
to simultaneously pressing the 4 transmitter keys or, after opening
the battery compartment, bridging the two P1 points by means of a
screwdriver (fig. B1A).
-
Read (read)
Checks one key of a receiver; if stored it displays a message showing
the receiver number in the memory location (from 01 to 64), and the
key number (T1, T2, T3 or T4).
-
Eliminate list (erease 64)
WARNING! Completely removes all memorised radio control devices
from the receiver memory.
Receiver code reading (RX code)
-
This displays the code entered in the receiver.
IMPORTANT NOTE: STICK THE AdHESIvE KEY LABEL ON THE FIRST
MEMORISEd TRANSMITTER (MASTER).
In the case of manual programming, the first transmitter assigns the RE-
CEIVER KEY CODE; this code is necessary in order to carry out subsequent
cloning of radio transmitters.
The on-board Clonix incorporated receiver is provided with a number of
advanced functions:
Cloning of master transmitter (rolling-code or fixed code)
Cloning by replacement of transmitters already inserted in the receiver
Management of transmitter database
Management of common receivers
To use these advanced function, refer to the
instructions and the CLONIX programming guide, supplied with the
palmtop
15.4) LANGUAGE MENU (language)
Allows you to set the language on the display programmer.
-
ITALIAN (ITA)
-
FRENCH (FRA)
-
GERMAN (DEU)
-
ENGLISH (ENG)
-
SPANISH (ESP)
15.5) DEFAULT MENU (default)
Restores the preset default values on the control unit. After restoring, a new
autoset operation must be carried out.
15.6) MENU' FAST NET (FAST NET)
After all connections have been carried out correctly (Fig. 16), it is neces-
sary to configure the FAST NET for the identification of the connected de-
vices. The FAST NET configuration for the identification of the connected
devices should be repeated whenever the connected devices are changed
(e.g. by adding or eliminating some of them).
- Find (find)
Press OK to perform identification of the devices.
the EEpr message and then a counter checking the network scanning;
once it reaches 255, FAST NET scanning is finished and the display will
show the sequence of the devices recognised.
to the devices actually connected.
- View (viev)
allows to visualise the stored devices using the menu scrolling keys.
WARNING: after completing the network scanning, use the "View" option on
the menu, to check that ALL the connected devices have been acquired.
15.7) DIAGNOSTICS AND MONITORING
The display on the NETTUNO S panel shows some useful information, both
during normal operation and in the case of malfunctions.
Diagnostics:
In the case of malfunctions, the display shows a message indicating which
device needs to be checked:
PED =
STRT =
STOP =
PHOT =
ENET =
TER =
CLOS =
OPEN =
programmer.
Pedestrian input activation
START input activation
STOP input activation
PHOT input activation
FAST NET failure
Test of safety devices unsuccessful
CLOSE input activation
OPEN input activation
DEIMOS BT - NETTUNO S-MA - Ver. 04 -
ENGLISH
Universal palmtop programmer
Universal
The display will first show
Check that they correspond
19

Publicité

loading

Ce manuel est également adapté pour:

Nettuno s-ma