Safety instructions
Residual hazards
(
Stop!
Possible overheating of the brake resistor during operation
Inadequate heat dissipation during operation can cause the brake
resistor to overheat.
Possible consequences:
ƒ
ƒ
Protective measures:
ƒ
ƒ
36
The brake resistor is destroyed.
The drive is not braked but coasts to a standstill.
Always connect the thermal contact of the brake resistor.
Integrate the thermal contact into the overall equipment
monitoring apparatus in such a way that the supply of power to
the standard device is switched off if the brake resistor overheats
(e.g. switch−off by means of mains contactor control).