Regular Maintenance - Tecno Air System Tosai SRE 301 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

WARNING!
When pumping fuel out of the tank, be sure to put out all flames,
and unplug the unit, otherwise it may cause imperfect combustion.
Water Drain/Oil Drain of Fuel Receiver
In such case that water is mixed into fuel, and that stops combustion,
take the following steps to drain water.
1.
Unplug the unit.
2.
Remove fuel strainer.
See the steps for the cleaning of fuel filter
on the previous page.
3.
Drain water/liquid combustible for mobile
heater.
Insert a fuel feeder through a hole on the
back panel, and pump out the content.
4.
Replace the fuel strainer.
Wipe out dripped water/oil around the strainer.
Absorb wasted water/oil into used newspapers and dispose them.
If imperfect combustion remains despite of the above procedure, contact your local
distributor or the nearest customer service agent.

REGULAR MAINTENANCE

It is recommendable to conduct the following regular maintenance
at least once every two years.
Every component parts of the unit goes inferior in quality as time passes.
It is suggested that regular check-up be taken once every two years so as to
maintain the unit at its best.
For more details on regular maintenance, contact your local distributor or the
nearest customer service agent.
Component parts subject to replacement:
Following items are tend to wear out in the long term of use;
.......Packing materials, fuel filter
Following items are tend to be affected by poor quality oils;
.......Electromagnetic pump, oil duct, burner body, flame rods, fuel filter, burner
head (metal net)