EXHAUSTING THE DRYER (cont.)
• DO cut duct as short as
possible and install straight
into wall.
• DO NOT bend
or collapse
ducting. Use
elbows if turns
are necessary.
EXHAUST LENGTH
Using exhaust longer than specified length will:
• Increase the drying times and the energy cost.
• Reduce the dryer life.
• Accumulate lint, creating a potential fire hazard.
The correct exhaust installation is YOUR
RESPONSIBILITY.
Problems due to incorrect installation are not
covered by the warranty.
RECOMMENDED MAXIMUM LENGTH
EXHAUST
LENGTH
Recommended
27"
NORMAL
4" DIA.
VENT
MODELS
No. of 90° Elbows
Rigid Metal
0
1
2
3
RECOMMENDED MAXIMUM LENGTH
EXHAUST
LENGTH
Recommended
27" LONG
VENT
4" DIA.
MODELS
No. of 90° Elbows
Rigid Metal
0
1
2
3
4
5
Installation Instructions
Exhaust Hood Types
Use only for short run
installations
4" DIA.
4" DIA.
4"
Rigid Metal
56 Feet
42 Feet
48 Feet
34 Feet
40 Feet
26 Feet
32 Feet
18 Feet
Exhaust Hood Types
Use only for short run
installations
4" DIA.
4" DIA.
4"
Rigid Metal
200 Feet
175 Feet
185 Feet
165 Feet
175 Feet
155 Feet
165 Feet
145 Feet
155 Feet
135 Feet
145 Feet
125 Feet
• DO NOT use
excessive
exhaust
length. Cut
duct as short
as possible.
The MAXIMUM ALLOWABLE length of the exhaust
system depends upon the type of duct, number of turns,
the type of exhaust hood (wall cap) and all conditions
noted on the chart.
• Internal elbows added for side or bottom vent
conversions must be included in the total elbow count.
• Any elbow greater than 45° should be treated as a 90°
elbow; one elbow of 45° or less may be ignored.
• Two 45° elbows will be treated like one 90° elbow. For
the side exhaust installations, add one 90° elbow to the
chart.
• For every additional 90° elbow, reduce the allowable
vent system length by 10 feet.
• When calculating the total vent system length, you
must add all the straight portions and elbows of the
system (including the transition duct).
2-1/2"
EXHAUST
LENGTH
24"
NORMAL
VENT
MODELS
2-1/2"
No. of 90° Elbows
0
1
2
13
• DO use elbows when turns are
necessary.
Elbows
• DO NOT
crush duct
against the
wall.
RECOMMENDED MAXIMUM LENGTH
Exhaust Hood Types
Use only for short run
Recommended
4" DIA.
4" DIA.
4"
Rigid Metal
43 Feet
33 Feet
24 Feet
• DO NOT
set
appliance
on duct.
installations
4" DIA.
2-1/2"
Rigid Metal
36 Feet
26 Feet
16 Feet

Publicité

loading

Ce manuel est également adapté pour:

Gud24gssmwwGuv27essmwwGud27espmdgGud27essmwwGud27gssmww