27" MODELS - CONNECTING AN ELECTRIC DRYER
CONNECTING DRYER USING 4-WIRE
CONNECTION (MUST BE USED FOR
MOBILE HOME INSTALLATION)
NOTE: Since January 1, 1996, the National Electrical
Code requires that new constructions use a 4-wire
connection to an electric dryer. A 4-wire cord must also
be used where local codes do not permit grounding
through the neutral.
3-wire connection is NOT for use on new construction.
REMOVE GROUND STRAP AND DISCARD.
KEEP GREEN GROUND SCREW.
4 # 10 AWG MINIMUM
COPPER CONDUCTORS
NEUTRAL
OR 120/240V 30A POWER
(White)
SUPPLY CORD KIT
MARKED FOR USE WITH
DRYERS & PROVIDED
WITH CLOSED LOOP OR
SPADE TERMINALS WITH
UPTURNED ENDS (NOT
SUPPLIED).
3/4" UL RECOGNIZED
STRAIN RELIEF
COVER
1. Turn off the circuit breaker(s) (30 amp) or remove
the dryer's circuit fuse at the electrical box.
2. Be sure the dryer cord is unplugged from the wall
receptacle.
3. Remove the power cord cover located on the back.
4. Remove and discard ground strap. Keep the green
ground screw for Step 7.
5. Install 3/4 in. UL-recognized strain relief to power
cord entry hole. Bring power cord through strain
relief.
6. Connect power cord as follows:
A. Connect the 2 hot lines to the outer screws of the
terminal block (marked L1 and L2).
B. Connect the neutral (white) line to the center of
the terminal block (marked N).
7. Attach ground wire of power cord with the green
ground screw (hole below strain relief bracket).
Tighten all terminal block screws (3) securely.
8. Properly secure power cord to strain relief.
9. Reinstall the cover.
NEVER LEAVE THE COVER OFF OF THE
TERMINAL BLOCK.
Installation Instructions
HOT WIRE
GREEN OR
YELLOW WIRE
RELOCATE
HOT
WIRE
GREEN GROUND
SCREW HERE
STRAIN
RELIEF
BRACKET
CONNECTING DRYER USING
3-WIRE CONNECTION
3 # 10 AWG MINIMUM
COPPER CONDUCTORS
OR 120/240V 30A POWER
SUPPLY CORD KIT
MARKED FOR USE WITH
DRYERS & PROVIDED
WITH CLOSED LOOP OR
SPADE TERMINALS WITH
UPTURNED ENDS (NOT
SUPPLIED).
SCREWS
(3)
3-wire Connection
NOT for use in Canada.
DO NOT use for Mobile Home Installations.
NOT for use on new construction.
NOT for use on recreational vehicles.
NOT for use in areas where local codes prohibit
grounding through the neutral conduction.
1. Turn off the circuit breaker(s) (30 amp) or remove
the dryer's circuit fuse at the electrical box.
2. Be sure the dryer cord is unplugged from the wall
receptacle.
3. Remove the power cord cover located on the back.
4. Install 3/4-in. UL-recognized strain relief to power
cord entry hole. Bring power cord through strain
relief.
5. Connect power cord as follows:
A. Connect the 2 hot lines to the outer screws of the
terminal block (marked L1 and L2).
B. Connect the neutral (white) line to the center of
the terminal block (marked N).
6. Be sure ground strap is connected to neutral
(center) terminal of block and to green ground
screw on cabinet rear. Tighten all terminal block
screws (3) securely.
7. Properly secure power cord to strain relief.
8. Reinstall the cover.
NEVER LEAVE THE COVER OFF OF THE
TERMINAL BLOCK.
11
GREEN GROUND SCREW
NEUTRAL
HOT
AND GROUND STRAP
(White)
WIRE
3/4" UL RECOGNIZED
STRAIN RELIEF
HOT
WIRE
COVER
SCREWS
(3)
STRAIN
RELIEF
BRACKET