Télécharger Imprimer la page

Simer Geyser Jr. 2110 Série Notice D'utilisation page 4

Publicité

Les langues disponibles

Les langues disponibles

Repair Parts / Troubleshooting
1
2
3
4
5
5A
6
TROUBLESHOOTING
Risk of electrical shock and sudden start.
Disconnect electrical power to pump before attempting to troubleshoot or work on it.
SYMPTOM
POSSIBLE CAUSE(S)
Pump won't
Blown fuse
start or run
Low line voltage
Defective motor
Clogged screen
Pump operates
Low line voltage
but delivers little
or no water
Small diameter garden hose
or long discharge line
Check valve installed without
vent hole
Coils or bends in hose
For parts or assistance, call Simer Customer Service at
REPAIR PARTS
Key
Part Description
1
Handle Screw
2
Power Cord (8 ft.)
3
Handle
4
Motor
5
Volute Assembly
5A
Pump Screen
6
Volute Screw
* Included in Key Item 5.
** If the motor fails, replace the entire pump.
CORRECTIVE ACTION
If blown, replace with fuse of proper size
If voltage under recommended minimum, check size of wiring
from main switch on property. If OK, contact power company
Replace pump
Remove volute, clean the screen and replace the volute
Use only 14 gauge or larger extension cords. Use short extension cords
when necessary
Use larger diameter garden hose or 1" flexible pipe. Eliminate any
excess hose. Short hoses work best
Drill a 1/16" - 1/8" (1.6 - 3.2 mm) dia. hole between pump
discharge & check valve
Straighten hose
1-800-468-7867 / 1-800-546-7867
4
Qty.
2110-01
2
670-646
1
227-264-B-TSU
1
383-147-B
1
**
1
404-160
1
*
6
670-646

Publicité