• Inverter Output Power Limit Timer: This button
adjusts the power limit timer.The default setting is 300
sec. Tap the Edit button to adjust the value in
10-sec increments. Use with the Inverter Output Power
Limit if pairing with a lithium ion battery. The timer is
automatically disabled if the maximum limit is selected.
• Transfer Mode: This button adjusts the line to battery
transfer time setting. The default setting is Appliance
(APL) at 20 ms. Tap the toggle button to change to the
uniterruptible power supply (UPS) setting of 10 ms.
Do not connect to the motor loads when the setting
I
is in UPS mode.
• Utility AC Under Voltage Level: This button sets the
minimum acceptable AC under voltage level from the
shore power if an under-voltage outlet exists. The
default setting is 90 V. Tap the Edit button to change
the minimum acceptable AC under voltage level.
• Battery Temperature: This button adjusts the
battery temperature setting. The default setting is Hot.
Tap the Edit button to select from Cold, Warm, or Hot.
Changing the battery temperature setting from Cold
I
to Warm will increase the charger voltage by 0.4 V.
Changing the battery temperature setting from Cold
to Hot will increase charger voltage by 0.8 V.
• Custom Absorption Voltage: This button adjusts
the absorption voltage for the custom battery type. The
default setting is 14.6 V. Tap the Edit button to adjust
the value in 0.1 V increments.
Available only for a custom battery type.
I
• Custom Float Voltage: This button adjusts the float
voltage level for the custom battery type. The default
setting is 13.5 V. Tap the Edit button to adjust the value
in 0.1 V increments.
Available only for a custom battery type.
I
EN
• Inverter Shutdown Recovery: This button sets the
restart method if the inverter shuts down due to an over
temperature, overload, or short circuit condition. The
default setting is a manual restart. Changing the setting
to auto-restart will cause the inverter to attempt to
restart automatically up to three times if a shut down
occurs. if the inverter is shut down for the fourth time,
additional restarts must be attempted manually, as
there may be a safety concern related to the shut
down. Tap the toggle button to allow a manual restart
via the display panel.
• Audible Alarm: This button toggles an alarm on or off
that beeps every 5 seconds. The default setting is On.
• Battery Type: This button sets the battery type. The
default setting is Flooded (FLd). Tap the Edit button to
change the battery type installed.
• Max Charger Current: This button adjusts the
maximum charging current allowed to charge the
batteries from the inverter. The default setting is 80 A.
Tap the Edit button to adjust the value in 5 A
increments.
• Equalize Charging: This button allows one hour of
equalized charging. The default setting is Off. Tap the
Start button to begin charging.
Available only for a Flooded battery type.
I
• AC Input Breaker - Load Share: This button adjusts
the load share setting to prioritize the AC load. The
charge current is reduced to maintain the total input
current at less than the load share setting. The default
setting is 30 A. Tap the Edit button to select the load
share setting.
Complete the following steps to change the default value
to a different value:
1. Tap the expand/contract button for the feature
setting that you want to update.
2. Based on the available options for the selected
feature, complete one of the following actions:
– Tap an option from the list.
– Tap the toggle button to activate/deactivate the
feature.
– Tap the EDIT button to view the available settings for
the value.