Changing the filter element:
1. Switch the product off at the device switch.
2. Prevent unintentional restarting by disconnecting the mains plug.
3. Remove the new filter element from the box and remove the sealing cap (Pos.3).
Please ensure the sealing ring (Pos. 2) is not damaged as you do this.
4. Remove the saturated filter element (Pos. 1) from the product by raising it slightly
and then pulling it out to the front.
5. Close off the intake opening on the filter element with the sealing cap from the
new filter element.
6. Push the new filter element (Pos. 1) back into the product mounting (Pos. 5) in the
reverse order. You must ensure that the sealing ring (Pos. 2) does not rub against
the sealing surface of the arm bracket (Pos. 6), otherwise it may be deformed or
destroyed.
1502762-00
Fig. 13: Changing filters