9. Storage
If you are not going to use the device for an extended period of time, disconnect it and store it in a dry place, out
of the reach of children.
10. Disposal
In the interest of protecting the environment, the unit must not be thrown out with the household
waste at the end of its service life. Dispose of the unit at a suitable local collection or recycling point.
Dispose of the device in accordance with EC Directive 2002/96/EC – WEEE (Waste Electrical and
Electronic Equipment). If you have any questions, please contact the local authorities responsible for
waste disposal.
11. What if there are problems?
Problem
Possible cause
Device does not
On/off button switched off
light up
No electricity
No electricity
The fluorescent tube is not correctly inserted
Fluorescent tube has reached the end of its
service life. Fluorescent tube is defective.
12. Technical specifications
Dimensions (WHD)
Weight
Lighting elements
Nominal data for replacement
lighting elements
Nominal data for starter
Power
Light intensity
Radiation
Mains connection
Degree of efficiency of the ballast
Source effiency (lm/W) of the bulb
Color temperature of tubes
Subject to technical modifications.
340 x 480 x 80 mm
2.625 kg
2 x 36 W tubes (2G 11), Daylight
Philips 2G 11, 36 W,
Osram/Dulux 2G 11, 36 W
AC 220 – 240 V, 4 to 65 W
72 watts
10.000 lux (15 - 20 cm)
Output of radiation beyond the visible spectrum (infrared and UV) is
so low that it is harmless to eyes and skin.
230 V ~, 50 Hz
~ 80%
67 lm/W
6.500 Kelvin
14
Solution
Switch on the on/off button.
Connect the mains plug correctly.
The mains cable is defective. Contact
customer services or your retailer.
Insert the fluorescent tube correctly
(Chapter 8).
Replace the fluorescent tube
(Chapter 8).