Carefully remove the cover to replace the tube.
3
4
Open the tube's two transparent retaining clips by pulling
up on them.
5
Carefully pull the tube up over the housing rim (1) and out
of the housing, then sideways out of the frame (2).
6
Insert the new tube by following these steps in reverse
order.
Replacing the starter:
7
Carry out steps 1 – 3 as described above.
Release the starter by turning it anti-clockwise (1)
8
(< ¼ turn), then pull it up and out (2).
Insert the new starter by following these steps in reverse
9
order.
10
Before screwing shut the unit, ensure that the retaining
clips are again sitting firmly against the tubes and that
you have not left any objects (such as packaging material,
plastic foil, etc.) in the unit.
Please use only the tubes and starter listed in the
technical specifications!