30
9. Operation & Malfunction
Possible operations and malfunctions of the airbag vest:
If you notice any other malfunctions, please contact your dealer or our after sales
service via e-mail sav@helite.com or by phone +33 3 80 35 48 26.
User Guide
System operational
Green flashing LED: No beep
Battery low
Orange flashing LED / 4 beeps during
airbag activation or deactivation
Battery charging
Orange LED / No beep
Charging completed
Green LED / No beep
when the charger is still connected
Pairing in process
Blue LED / 1 beep every 5 sec.
during 30 sec.
Success of pairing
Blue LED / 1 beep every 2 sec.
2 short beeps when the sensor is already
recognized
Pairing failed
Red LED / 4 beeps
or too many sensors recognized by the vest
Disconnected e-cartridge, empty
e-cartridge or damaged cable.
Red LED / 1 beep every second
while the e-cartridge is not connected or
replaced
You can ride.
You need to
recharge the vest.
You can still
ride for 2 hours.
Wait until the end
of the charging.
Unplug the
charger.
You have 30 sec.
to pair the fork
sensor.
The vest and the
fork sensor are
paired.
Restart the
pairing.
Connect the
e-cartridge.