Simple troubleshooting
Problem
The default settings have
been changed and need to
be reset.
LEDs
lash.
LEDs
lash.
LEDs
lash.
If you are unable to solve the problem, please call the hotline.

Technical speciications

Electrical connection (voltage/frequency)
Heating output
Maximum pump pressure, static
Maximum water tank capacity (without ilter)
Maximum bean container capacity
Cable length
Dimensions (H x B x D)
Weight, unilled
Type of grinding unit
TES501_1DE.indb 39
Cause
Some settings have been
made that are no longer
required.
The appliance has a fault.
Incorrect voltage.
The ambient temperature is
too cold.
Remedy
Press the power on/off but­
ton O / I (9) to switch off the
appliance. Press and hold
the service button (12) and
the steam button (11) and
press the power on/off but­
ton O / I (9) to switch on the
appliance. Then press the
start button (10) to conirm.
The default settings are
reset.
Please contact the hotline.
Operate the appliance at
220 V­240 V only.
Operate the appliance at
temperatures > 5° C.
220­240 V / 50­60 Hz
1600 W
15 bar
1.7 l
300 g
100 cm
385 x 280 x 479 mm
9.3 kg
Ceramic
TES501.. 08/2011