Setting Up The Compressed-Air Motor En - Abicor Binzel BRS-CC Guide D'installation

Masquer les pouces Voir aussi pour BRS-CC:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

BRS-CC
6.7 Setting up the compressed-air motor
1
Clamping device
2
Gas nozzle
Fig. 9
Setting up the compressed-air motor
 Fig. 5 Putting into operation on page EN-12
1 Loosen the compressed-air motor from the guide block (4) by removing the screws (3).
2 Pull back the compressed-air motor (5) in its fastener.
3 Place the required distance sleeve (7) on the reamer (6).
4 Move the torch with the gas nozzle (2) to the clamping position (P2).
5 Keep the guide block (4) in the lower position (stroke down).
6 Place the compressed-air motor (5) against the gas nozzle (2) with the distance sleeve (7) placed on
top.
7 Secure the adjusted motor position using the screws (3).
8 Move the torch out of the clamping device (1) and remove the distance sleeve (7) from the reamer (6).
NOTICE
• Make sure that only clean and dry compressed air is used.
1
7
6
5
3
Screws
4
Guide block
The compressed air must correspond at least to the quality class 4 according to ISO 8573-1.
2
3
4
5
Compressed-air motor
6
Reamer
6 Putting into operation
7
Distance sleeve
EN - 15