Hilti TE 80-ATC Mode D'emploi page 19

Masquer les pouces Voir aussi pour TE 80-ATC:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 30
2.3 Switches
Speed control switch for smooth starting
Function selector switch: Hammer drilling, chiseling, chisel adjustment (24 positions)
Power selector switch for full or reduced (50%) power (optional)
Control switch lockable for chiseling
2.4 Grips
en
Vibration-absorbing, pivotable side handle
Vibration-absorbing grip
2.5 Protective devices
Mechanical safety clutch
Electronic restart interlock to prevent the power tool starting unintentionally after an interruption in the electric supply
(see section 9 "Troubleshooting").
Additional ATC "Active Torque Control" (TE 80‑ATC/ TE 70‑ATC)
2.6 Lubrication
Gearing and hammering mechanism with separate lubrication chambers
2.7 TPS Theft Protection System (optional)
The power tool may be equipped with the TPS Theft Protection System as an option. If the power tool is equipped
with this feature, it can be unlocked and made ready for operation only through use of the corresponding TPS key.
2.8 Active Vibration Reduction (only TE 80‑ATC)
The power tool is equipped with an AVR Active Vibration Reduction system which reduces vibration significantly
compared to power tools without AVR.
2.9 LED indicators
Service indicator LED (see section "Care and maintenance")
Theft protection system indicator (optional) (see section "Operation")
50% power indicator (optional) (see section "Operation")
2.10 Items supplied as standard
1
Power tool
1
Side handle
1
Grease
1
Cleaning cloth
1
Operating instructions
1
Hilti toolbox
2.11 Using extension cords
Recommended minimum conductor cross section and max. cable lengths
Conductor cross section
Mains voltage 100V
Mains voltage 110-127 V
Mains voltage 220-240 V
2.12 Using a generator or transformer
This power tool may be powered by a generator or transformer when the following conditions are fulfilled: The unit
must provide a power output in watts of at least twice the value printed on the type identification plate on the power
tool. The operating voltage must remain within +5% and -15% of the rated voltage at all times, frequency must be in
16
1.5 mm²
2.0 mm²
30 m
20 m
30 m
30 m
2.5 mm²
3.5 mm²
50 m
40 m
75 m